YAMUNA EXPRESSWAY INDUSTRIAL DEVELOPMENT AREA BUILDING
REGULATIONS, 2010
PREAMBLE
In exercise of the powers under sub-section 2 of
section 9 and section 19 of the Uttar Pradesh Industrial Area Development Act
1976 (U.P. Act no-6 of 1976) read with section 21 of the Uttar Pradesh General
Clauses Act, 1904 (U.P. Act no-1 of 1904) and in supersession of notification
no. 1582/77-3-09-8X/09, dated-September 09, 2009 the Yamuna Expressway
Industrial Development Authority hereby makes the following regulations with
the prior approval of the State Government to regulate the erection of building
within the Yamuna Expressway Industrial Development Area;
CHAPTER -1
PRELIMINARY
Regulation - 1. Short title, commencement and application.
1.1 These regulations may be called the Yamuna
Expressway Industrial Development Area Building Regulations, 2010.
1.2 They shall come into force with effect from
the date of their publication in Gazette.
1.3 Chapter 1 to IV shall apply to building
activities within the urban sable area and Chapter V, shall apply to the area
designated for agricultural use by the Authority.
1.4 These regulations shall be applicable for
Yamuna Expressway Industrial Development Area.
1.5 Chapter VI shall apply to the plots allotment
to the farmers against their land acquisition (5% to 7% of the acquired land as
per policy of the Authority)
1.6 The plots on which map has already been
sanctioned and construction has already been started or completed, the allottee
may be allowed to revise the same building plan or submit the new plan as per
prevailing regulations for that part of building where construction has not
started or any new addition required in building.
1.7 F.A.R., Ground coverage, setbacks and density
as indicated in these regulations shall not be applicable in respect of those
plots which were allotted on auction or tender basis and group housing prior to
the coming into operation of these regulations. However the calculation of FAR
and Ground Coverage in the new buildings in such plots shall be done as per
these regulations. The purchasable F.A.R and Ground coverage as per
applicability may be allowed.
1.8 Notwithstanding anything contained in these
regulations, the special provisions contained in the-
(a) lease deed executed before commencement of these regulations, and
(b) bids accepted by the Authority before commencement of these regulations shall continue to be effective unless amended with the consent of the
lessee/sublessee
Regulation - 2. Definitions.
In these regulations, unless the context otherwise
requires,-
2.1 'Act' means Uttar Pradesh Industrial Area
Development Act, 1976 (U.P. Act No. 6 of 1976.
2.2 'Air conditioning' means the process of
treating air so as to control simultaneously its temperature, humidity,
cleanliness and distribution to meet the requirement of conditioned space.
2.3 'Alteration' means the structural change, such
as addition to the area or height or the removal of part of a building, or
construction of cutting into or removal of any wall, partition, column, beam,
joint, floor or other support, or a change to the fixtures or equipments of the
building.
2.4 'Applicant' means the person who has legal
title to a land or building and includes,
(i) An agent or trustee who receives the rent on behalf of the owner;
(ii) An agent or trustee who receives the rent of or is entrusted with or is
concerned with any building devoted to religious or charitable purposes;
(iii) A receiver, executor or administrator or a manager appointed by any
Court of competent jurisdiction to have the charge, or to exercise the rights
of the owner; and
(iv) A mortgagee in possession.
2.5 'Approved' means approved by the Yamuna
Expressway Industrial Development Authority.
2.6 'Area' means the Industrial Development Area
as notified for the Yamuna Expressway Industrial Development Authority.
2.7 'Authorised Officer' means an officer
authorized by the Chief Executive Officer.
2.8 'Atrium' - A sky lighted central area, often
containing plants, in modern buildings especially for common area.
2.9 'Balcony' means a horizontal projection
including a handrail or balustrade to serve as sitting out place.
2.10 'Basement or Cellar' means the lower storey of
a building below or partly below ground level.
2.11 Building' means any permanent structure or
erection or part of a structure or erection which is intended to be used for
residential, commercial, industrial, institutional, recreational or other
purposes for the use and benefit of human being whether in actual use or not.
2.12 'Building activity' means erection,
re-erection, making material alteration, or demolition of any building.
2.13 'Building height' means the vertical distance
measured in the case of the flat roofs from the top level of the adjoining
drain to the highest point of the building and in the case of sloping roof the
mid point between the eaves level and the ridge. Architectural features serving
no other functions except that of the decoration shall be excluded for the
purpose of measuring heights.
2.14 'Building line or envelope' means a line up to
which the plinth of a building may be lawfully extended. It includes lines
specifically indicated or to be indicated in any scheme or layout plan or in
these regulations.
2.15 'Canopy' means a projection over any entrance
and if provided in setbacks shall be either cantilevered or supported on
columns.
2.16 'Chajja' means a sloping or horizontal
structure overhung usually provided for protection from sun and rain or for
Architectural considerations.
2.17 'Direction' means the direction issued by the
Authority under Section 8 of the Act, and would include, unless the context
otherwise indicates, any executive instructions issued here under.
2.18 'Drain' means a conduit or channel for the
carriage of storm water or other used water.
2.19 'Drainage' means the removal of any liquid by a
system constructed for this purpose.
2.20 'Dwelling Unit' means an independent housing
unit with separate facilities for living, cooking and sanitary requirements.
2.21 'Evergreen tree' means tree that remains green
for most part of the year and sheds leaves slowly throughout the year.
2.22 'Existing building or use' means building
structure or its use as sanctioned/approved by the competent authority, or
existing before the declaration of the notified area of respective Authority.
2.23 'Extended Basement' means the construction of
floor(s) below the ground leaving a minimum setback of 6.0 metre all-round from
the plot boundary for the purpose of fire tender movement. The top slab of
basement to flush with the ground level and such slab to be designed for fire
tender load with adequate mechanized ventilation.
2.24 'Floor' means the lower surface in the storey
on which one normally walks in building.
2.25 'Floor Area Ratio (FAR)' means the quotient
obtained by dividing the total covered area (plinth area) on all floors by the
area of plot.
2.26 'Foundation' means that part of the structure,
which is in direct contact and transmitting loads to the ground.
2.27 'Green Building' A green building is one which
uses less water, optimizes energy efficiency, conserves natural resources,
generates less waste and provides healthier spaces for occupants, compared to a
conventional building.
2.28 'Group Housing' means a premises of size not
less than 2000 sq. mtrs. comprising of either residential flats or a cluster of
flats and independent houses/villas, with basic amenities like parking, park,
convenience shop, public utilities, etc.
2.29 'Hazardous Buildings' means a building or part
of a building which is used for the storage, handling, manufacturing or
processing of highly combustible or explosive materials or products which are
liable to burn with extreme rapidity or which may produce poisonous fumes or
explosions, or the storage or handling or manufacturing or processing of highly
corrosive, toxic or noxious alkalis, acids or other liquids or chemicals
producing flame, fumes or explosive, poisonous, irritant or corrosive gases and
the storage, handling or processing of any material producing explosive
mixtures of dust or which result in the division of matter into the fine
particles subject to spontaneous ignition.
2.30 'Hard Landscape' means the Civil work component
of landscape architecture such as pavement, walkways, roads, retaining walls,
sculptures, street activities, fountains and other built environment.
2.31 'Hedge' means number of shrubs or trees (often
similar species) planted closely together in the line. A hedge may be pruned to
shape or allowed to grow to assume its natural shape.
2.32 'Jali' means A grill or screen made of metal,
brick, ferro-cement, wood or any other material which is placed in front of a
window, door or any opening or piece of machinery in order to protect it.
2.33 'Layout Plan' means a plan of the entire site
showing location of plots/building blocks, roads, open spaces, entry/exits,
parking, landscaping etc. indicating the activity for all land parcels.
2.34 ' Technical Person' means an architect/civil
engineer/town planner recognized by the Authority as per Appendix 12.
2.35 'Loft' means an intermediary floor between two
floors or a residual space in a pitched roof above normal floor level with a
maximum height of 1.5 metres and which is constructed or adopted for storage
purpose.
2.36 'Development Plan' means the Development
Plan/Master Plan of the Authority in respect of the Area prepared by the
Authority.
2.37 'Mezzanine floor' means an intermediate floor,
between two floors, above ground level, accessible only from the lower floor.
2.38 'Multi Level Parking' means a separate block or
a part of any building on a property to be used primarily for parking of
vehicles through mechanized or conventional methods,.
2.39 'Mumty or Stair cover' means a structure with a
covering roof over staircase and its landing built to enclose only the stairs
for the purpose of providing protection from weather and not used for human
habitation.
2.40 'Mixed Land use' means mixing/planning of
compatible uses, horizontally or vertically, on a property, such as commercial,
offices, residential or institutional.
2.41 'Occupancy' means the main purpose for which a
building or a part of a building is used or intended to be used and
classification of a building according to occupancy shall deem to include
subsidiary occupancies which are contingent upon it.
2.42 'Open Space' means a space forming an integral
part of the plot left open to the sky.
2.43 'Owner' means a person, group of persons, a
company, trust, registered body, State or Central Government and its departments,
undertakings and like in whose name the property stands registered in the
relevant records.
2.44 'Parking space' means a space enclosed or
unenclosed to park vehicles together with a driveway connecting the parking
space with a street permitting ingress and egress of the vehicles.
2.45 'Permit' means a permission or authorization in
writing by the Authority to carry out the work regulated by these regulations.
2.46 'Planning and Development Directions' means
Directions issued by the Authority under Section 8 of the Act for defining
architectural features, facades of the buildings, maintenance of amenities etc.
from time to time, and would include, unless the context otherwise indicates,
any executive instructions issued hereunder.
2.47 'Pergola' means a perforated slab constructed
in such a manner that at least 50% of which is open to sky.
2.48 'Purchasable FAR' means the additional FAR,
which an old allottee can purchase over and above the FAR that was specifically
allowed to him at the time of allotment. The maximum purchasable FAR shall be
allowed up to the maximum limit of applicable FAR in these regulations
2.49 'Plinth' means a portion between the surface of
the surrounding ground and surfaced floor immediately above the ground.
2.50 'Plot' means a piece of land enclosed by
definite boundaries.
2.51 'Podium parking' means floor/floors above
ground, of maximum 2.4 mtrs. height each below the bottom of beam, if served by
a ramp for movement of vehicles for entry and exit from parking area or
alternatively mechanized parking as per standard plan by the registered company
undertaking such construction and duly approved by the competent Authority.
Ramp for podium shall not be allowed in the setbacks.
2.52 'Refuge Area' means For all building
exceeding 24 metres height, refuge area of 15 sq mtrs shall be provided as
follows:
(i) The refuge area shall be provided on the periphery of the plot or
preferably on a cantilever projection and open to air on atleast one side
protected with suitable railings.
(a) The floors above 24 metres and up to 39 metres- one refuge area on the
floor immediately above 24 metres.
(b) For floors above 39 metres - one refuge area on the floor immediately
above 39 metres and so on after every 15 mtrs.
(ii) Residential flats in multi-storeyed buildings with balconies need not be
provided with refuge area, however flats without balcony shall provide refuge
area as above.
2.53 'Road/Street/Right of Way' means any highway,
street, lane, pathway, alley, stairway, passage way, carriage way, footway
square, bridge, whether a thorough -fare or not, place on which the public have
a right of passage, access or have passed and had access uninterruptedly for a
specified period or whether existing or proposed in any scheme, and includes all
bunds, channels, ditches, storm water drains, culverts, side walks, traffic
islands, roadside trees and hedges, retaining walls, fences, barriers and
railings within the street lines.
2.54 'Road/Street Line' means the line defining the
side limits of a street/road.
2.55 'Road/Street Width' means distance between
boundaries of the road measured at right angles to the course of the road. 2.56
'Rain Water Harvesting' means utilizing rain water for recharging of ground
water, sanitation, irrigation etc. by adopting various techniques approved by
the Authority.
2.57 'Service floor' means a storey of maximum 2.40
mtrs. height below the beam between any two storeys to be used for running
electrical cables, water or sewerage lines, service ducts or AC ducts and services
and their maintenance only.
2.58 'Setback' means a specified line parallel to
the plot boundaries.
2.59 'Soft Landscape' means the natural elements in
a landscape design, such as plant materials and the soil itself.
2.60 'Storage' means a place where goods of non
hazardous nature are stored and including bank safe vault and cold storage.
2.61 'Table' means a table annexed to these
regulations.
2.62 'To abut' with its geometrical variations and
cognate expressions means abutting on road in such a manner that any portion of
the building is on the road boundary.
2.63 "Temporary Building"- means any
structure or erection or part of structure or erection which is intended to be
used only for temporary purpose for a definite period and which is made of
temporary and quickly removable building material such as canvas cloths, straw,
mat, hay, tarpaulin, asbestos sheets/plastic sheets, etc, without any permanent
foundation, wall, beam, column, slab using bricks, stone, reinforcement
concrete and such other materials of permanent nature.
2.64 "Unsafe Building'" building which
structurally and constructionally unsafe or unsanitary or not provided with
adequate means of egress or which constitute a fire hazard or otherwise
dangerous to human life or which in relation to existing use constitute a
hazard to safety or health or public welfare, by reason of inadequate
maintenance, dilapidation or abandonment.
2.65 'Urbanisable Area' means the area earmarked for
any of the following uses in the Development Plan/Master Plan.
(i) Residential;
(ii) Commercial;
(iii) Industrial;
(iv) Institutional;
(v) Green area
(vi) Transportation, and
(vii) Any other Special uses as specified in the Development Plan/Master
Plan/Scheme duly approved by the Authority.
Regulation - 3. Note.
The words and expressions used but not defined in
these regulations and defined in the Act, shall have the meanings assigned to
them in the Act, If not defined in the Act or these regulations, shall have the
meaning assigned to them in the Master Plan/Development Plan, National Building
Code, Indian Standard Institution Code as amended from time to time. In case of
any contradiction, the provisions of the Act shall prevail.
CHAPTER – II LAYOUT/BUILDING PERMIT AND OCCUPANCY
Regulation - 4. Building permit.
No person shall erect any building or a boundary
wall or fencing without obtaining a prior permit thereof, from the Chief
Executive Officer or an Officer authorized by the Chief Executive Officer for
this purpose.
Regulation - 5. Application for building permit.
(1) Every person who intends to erect
a building within the Industrial Development Area shall give application in the
Form given at Appendix - 1.
(2) The application for building
permit shall be accompanied by documents as mentioned in checklist annexed to
Appendix - 1.
(3) Such application shall not be
considered until the applicant has paid the fees mentioned in Regulation no.
10.
(4) In case of objections, the fees
so paid shall not be refunded to the applicant but the applicant shall be
allowed to resubmit the plan without any additional fees after complying with
all the objections within a period of sixty days from the date of receipt of
the objection order. If plan is submitted after sixty days, fresh plan fee
shall be charged.
(5) No application for building
permit shall be necessary for the following additions/alterations provided they
do not violate any of the provisions regarding general building requirements,
structure stability and fire safety requirements specified in National Building
Code-
(a) Whitewashing and painting;
(b) Plastering, patch work, flooring.
(c) Renewal of roof at the same
height;
(d) Reconstruction of portions of
building damaged by any natural calamity to the same extent as previously
approved;
(e) Internal additions/alterations
within the building envelop certified and supervised by a Technical Person;
(f) Digging or filling of earth;
Regulation - 6. Information Accompanying Application For Layout Plan Or Building Permit.
6.1 Layouts regarding
sub-division of land The site plan shall show,
(i) The boundaries of the plot and
the name and number of the properties and road abutting the plot;
(ii) Plot number of the property on
which the building is intended to be erected;
(iii) All existing buildings and
physical features standing on, over or under the site;
(iv) Building envelope at each floor
level in relation to the site;
(v) The total plot area and the
break-up of area under different uses, roads and open space with their
percentages with reference to the total area of the plot;
(vi) Total floor area ratio, ground
coverage and height of the building of each category proposed;
(vii) Setbacks of total plot as well as
individual proposed plots;
(viii) Details of setback, floor area
ratio, ground coverage, on each irregular shaped plots in the proposed layout
on at least 1: 500 scale;
(ix) Sewerage and drainage lines up to
discharge point and water supply lines;
(x) Details of boundary wall, plinth,
culvert and ramp, trees;
(xi) Scale used and the direction of
north point relating to plan of proposed building;
(xii) Parking plans indicating the
parking spaces for all the buildings;
(xiii) Landscape plan;
(xiv) Location and size of temporary
structures like stores, labour hutments, site office and such like, and
(xv) Electrical load requirement.
(1) Building Plan:
For any proposed structure, requirement of building
plan shall be as per clause 6.2, 6.3 and 6.4 as the case may be.
(2) Service Plans -
Details of private water supply and sewage disposal
system independent of the Municipal Services, if any and rain water harvesting
system, solar passive architecture as per Uttar Pradesh Government orders.
(3) Specification -
General specification of materials to be used in
different parts of the building as given in Appendix -6.
(4) Documents -
as per Checklist 1C annexed to Appendix 1
6.2 Residential building on plots other than group housing (flatted):
(1) The plan shall show-
(i) Key Plan -
A key plan drawn to a scale of not less than 1:1000
shall be submitted along with the application for a building permit showing the
boundary locations of the site with respect to neighbourhood landmarks;
(ii) The boundaries of the plot and
the name/number of the properties and road abutting the plot;
(iii) Plot number of the property on
which the building is intended to be erected;
(iv) All existing building and
physical features standing on, over or under the site,
(v) Building envelope at each floor
level in relation to the site,
(vi) The total plot area and the
break-up of covered areas on each floor with their percentages with reference
to the total area of the plot;
(vii) Total height of the building;
(viii) Setbacks;
(ix) Details of projections and
structures in setbacks;
(x) Sewerage and drainage lines upto
discharge point, rain water harvesting and water supply lines;
(xi) Details of boundary wall and its
plinth, culvert and ramp, trees, concealing of water tank on roof with jali;
(xii) Car parking, if applicable;
(xiii) Scale used and the direction of
north point relating to plan of proposed building;
(2) Documents as per Checklist 1-B
enclosed with Appendix -1.
(3) Specification: General
specifications of materials to be used in different parts of the building as
given in Appendix -6.
6.3 Other buildings
6.3.1 The site plan shall show:
(i) The boundaries of the plot and
the name/number of the properties and roads abutting to the plot;
(ii) Plot number of the property on
which the building is intended to be erected;
(iii) All existing buildings and
physical features standing on, over or under the site;
(iv) Building envelope at each floor
level in relation to the site;
(v) The total area and the break-up
of covered areas on each floor with their percentages with reference to the
total area of the plot;
(vi) Total height of the building;
(vii) Setbacks;
(viii) Details of projections and
structures in setbacks;
(ix) Sewerage and drainage lines upto
discharge point and water supply lines;
(x) Details of boundary wall, plinth,
culvert and ramp, trees;
(xi) Scale used and the direction of
north point relating to plan of proposed building;
(xii) Parking plan indicating the
parking spaces of all the buildings;
(xiii) Landscape plan;
(xiv) Location and size of temporary
structures like stores, labour hutments, site office; and
(xv) Electrical load requirement.
(xvi) Location and details of
facilities to be provided for physically challenged persons.
6.3.2 Building Plan -
The plan of the building, elevations and sections
shall be drawn to a scale not less than 1:200
(i) The plan shall include all floor
plans of the building together with the covered area;
(ii) The plan shall specify the use of
all parts of the building;
(iii) The plan shall show water supply,
sewerage, drainage lines and the like;
(iv) The plan shall include sectional
drawing showing clearly the thickness of walls, size and spacing of framing
members and floor slabs. The sections shall also indicate the height of the
rooms and the parapet. At least one cross section shall be taken through the
staircase;
(v) The plan shall show all street
elevations;
(vi) The plan shall include terrace
plan indicating the drainage and the slope of the roof;
(vii) The plan shall give dimension of
the permissible projections in setbacks;
(viii) The plan shall give direction of
the north point in relation to the plan and scale used.
6.3.3 Building plans for all
types of multi -
storeyed buildings -For multi -storeyed buildings
which are more than 15 metres in height, the following additional information
shall be indicated in the building plans in addition to those mentioned in
regulation 6.3.2;
(i) Access for fire appliances and
vehicles and details of vehicular turning circle and clear motorable access way
around the building;
(ii) Size (width) of main and
alternate staircase along with balcony, corridors and ventilated lobby
approach;
(iii) Location and details of lift
enclosures;
(iv) Location and size of fire lift;
(v) Smoke stop lobby doors, if
provided;
(vi) Refuge area, refuge chutes,
refuge chamber, service ducts, etc. if any;
(vii) Air conditioning system, if
provided, with position of dampers, mechanical ventilation system, electrical
services, boilers, gas pipes or the like;
(viii) Details of exits including
provision of ramps for hospital and special lifts;
(ix) Location of generator,
transformer and switch gear room;
(x) Smoke exhauster system, if any;
(xi) Details of fire alarm system;
(xii) Location of centralized control,
connecting all fire alarm system, built in fire protection arrangements and
public address system;
(xiii) Location and dimension of static
water storage tank and pump rooms with fire fighting inlets for mobile pump and
water storage tank;
(xiv) Location and details of first aid
and fire fighting equipment and installations;
(xv) Location and details of fixed
fire protection installations such as sprinklers, wet risers, hose-reels,
drenchers, CO2 installation, etc.
(xvi) Location and details of
facilities to be provided for physically challenged persons.
6.3.4 Service Plans -
Details of private water supply and sewage disposal
system independent of the Municipal Services, if any and rain water harvesting
system and solar passive architecture as per the Government of Uttar Pradesh
orders.
6.3.5 Specification -
General specification of materials to be used in
different parts of the building as given in Appendix -6.
6.3.6 Documents -
as per Checklist 1B annexed to Appendix 1.
6.4 Temporary Building
6.4.1 The site plan shall show:
(i) The boundaries of the plot and
the name/number of the properties and roads abutting the plot;
(ii) Plot number of the property on
which the building is intended to be erected;
(iii) All existing buildings and
physical features standing on, over or under the site;
(iv) Total height of the building;
(v) Setbacks;
(vi) Details of projections and
structures in setbacks;
(vii) Sewerage and drainage lines upto
discharge point and water supply lines;
(viii) Scale used and the direction of
north point relating to plan of proposed building;
(ix) Location and size of temporary
structures like stores, labour hutments, site office or such like temporary
structures.
6.4.2 Building Plan -
The plans shall be submitted for building other than
labour hutment. The plan of the building, elevations and sections accompanying
the application shall be drawn to a scale not less than 1:200
(i) The plan shall include all floor
plans of the building together with the covered area;
(ii) The plan shall specify the use of
all parts of the building;
(iii) The plan shall show water supply,
sewerage, drainage lines and the like;
(iv) The plan shall include sectional
drawing showing clearly the thickness of walls, size and spacing of framing
members and floor slabs. The sections shall also indicate the height of the
rooms and the parapet;
(v) The plan shall show all street
elevations;
(vi) The plan shall give indication of
the north point in relation to the plan and scale used.
6.4.3 Specification -
General specification of materials to be used in
different parts of the building as given in Appendix -6.
6.4.4 Documents -
as per Checklist 1 D annexed to Appendix 1.
Regulation - 7. Site.
plan shall be drawn to a scale as follow:
TABLE
|
Site area Scale
Up to 0.1 hectare
|
Not less than 1:200
|
|
Up to 0.1 hectare-1 hectare
|
Not less than 1:500
|
|
More than 1 hectare
|
Not less than 1:1000
|
Regulation - 8. Recommended notation for colouring of plans.
The site and building plans shall be coloured as
specified in the table given below. Where items of work are not identified, the
colouring notation used shall be indexed:
|
S. No.
|
Item
|
Site Plan
|
Building Plan
|
|
1.
|
Plot lines
|
Thick green
|
Thick green
|
|
2.
|
Existing street
|
Green
|
........
|
|
3.
|
Permissible building line
|
Thick dotted green
|
........
|
|
4.
|
Existing work (Outline)
|
Green
|
Green
|
|
5.
|
Work proposed to be demolished
|
Yellow hatched
|
Yellow hatched
|
|
6
|
Proposed
a) Additions/Alterations.
b) Entirely new work
|
Red
Not to be
coloured
|
Red
Not to be
coloured
|
|
7.
|
Drainage
|
Red dotted
|
Red dotted
|
|
8.
|
Water Supply
|
Green dotted thin
|
Green dotted thin
|
Regulation - 9. Preparation and signing of Plans.
All plans shall be prepared and signed by Technical
Person as per Appendix - 12.
Regulation - 10. Building permit fee, completion fees, temporary building permit fees and calculation thereof.
(1) Applicant shall deposit building
permit fees as follows:
(i) For all type of buildings Rs.
15.00 per square metre covered area on all floors.
(ii) For layout plan - Re. 1/- per
square metre plot area upto for first 4.0 ha and Re. 0.50 per square metre for
balance area.
(2) In case of re-erection of
existing building after demolition, permit fees chargeable shall be the same as
erection of new buildings.
(3) The permit fee for revised plan
of a building which has already been sanctioned, shall be one fourth of the fee
chargeable on the fresh plan, subject to the condition that the covered area of
the building shall not increase.. In case of increased covered area fresh
permit fee will be charged.
(4) The area covered in the basement,
stilt, podium, services area and all other covered area as the case may be,
shall be counted towards the covered area for purpose of calculation of permit
fees.
(5) The revalidation fee of a
building permit for 5 years shall be 10 per cent of the fresh building permit
fee, if the application is made within the period of validity of the building
permit. The application is made after the validity period, then the
revalidation fee shall be original building permit fee.
(6) In case of construction without
applying for building permit a compounding charges at the rate of Rs. 1000/-
per square metre of covered area shall be levied, provided all the provisions
as per Building Regulations are complied with.
(7) In case of construction without
revalidation, a fees of Rs. 10 per square metre of covered area shall be levied
if all provisions as per byelaws are complied with.
(8) In case of revision in layout
plan, permit fees shall be charged @ Rs. 0.50 per sq mtrs. for portion of plot
area of which the layout is submitted for sanction or completion.
(9) Malba charges of Rs. 10.00 per
square metre shall be levied over total covered area for all buildings on the
plot up to 2000 sqmtr, Rs. 5.00 per squire meter on plots of 2001 to 10000
sqmtr, and Rs. 2.00 per sqmtr. on plots above 10000 sqmtr.
(10) The applicant shall deposit
completion fees as follows:
(i) For all type of buildings Rs.
10/- square metre of covered area on all floors.
(ii) For layout plan - Re. 0.5/- per
square metre plot area for first 4.0ha acres and Re. 0.25 per square metre for
balance area.
(iii) In case even after two objection
letters issued by Authority if rectification of all objections is not done then
Rs. 500/- shall be levied towards site visit fees for each subsequent visit.
(11) The applicant shall deposit 25
percent of the building permit fees for temporary structures other than labour
hutments as per individual use of the structure. For labour hutments fees shall
be Re. 0.25 per square metre of covered area. Temporary structure shall be
allowed till completion of the building.
(12) Water, sewer and other service
connection charge shall be paid as levied by the Authority
(13) The Authority shall be competent
to revise the rate/amount of fees/charges mentioned in these Regulation.
Regulation - 11. Withdrawal of application.
The applicant may withdraw his application for a
building permit at any time prior to the sanction and such withdrawal shall
terminate all proceedings with respect to such applications but the fees paid
shall in no case be refunded.
Regulation - 12. Scrutiny of the building permit.
(i) The Authorized Officer shall
verify or cause to be verified the facts given in the application for permit,
and enclosures. The title of the land shall also be verified. All documents
submitted with the plans should be self attested by the owner and
Architect/Authorised Technical person.
(ii) The Authorized Officer shall
examine the information listed in regulation 6.3 for residential buildings on
plots (other than Group Housing).
(iii) For layout plan, buildings and
other temporary structures the Technical Person shall provide the information
in regulation 6.3, 6.4 and 6.5 respectively and provision of fire safety
requirements, public convenience, safety provisions and other relevant laws.
The Authorised/Technical Person shall also be responsible for all other
provisions as per Building Regulations, Planning and Development Directions,
National Building Code, Indian Standard Institution standards and such other
provisions as required by the Authority from time to time.
(iv) The Owner and Technical Person
shall jointly and severely liable and all of them shall submit indemnity bond
in favour of the Authority against violation of these Regulations, Planning and
Development Directions and provisions of National Building Code.
(v) The Authority, however reserves
the right to perform test checks by complete scrutiny of any of the plans
submitted for approval.
(vi) In case of any violation, the
Technical Person shall be black listed under intimation to concerned
registration organisation from practicing in the Industrial Development Area
for a period of 5 years.
(vii) In case owner is found
responsible for violation, action may be taken as per provision in lease deed.
Regulation - 13. Sanction or refusal of building permit.
(1) After filing of the application
for building permit duly certified by the Technical Person as per Appendix 4,
the applicant can commence the construction in accordance with the requirements
of Zoning Regulations of Development Plan/Master Plan, these Regulations or
Planning, Development Directions and terms of lease deed. In case any
objections are found during scrutiny of the plans, the same shall be got
rectified by the applicant and if any violations are found during or after the
construction, the owner shall be required to rectify the same to the
satisfaction of the Authority within a period of 30 days from the date such
violations are intimated to the owner. In case the owner fails to comply, the
Authority shall ensure compliance and the expenditure incurred on doing so
shall be recovered from the owner before issue of occupancy certificate.
(2) If within sixty days of the
receipt of the application, refusal or sanction is not granted, the application
with its annexures shall be deemed to have been allowed and the permit
sanctioned, provided such fact is immediately brought to the notice of the
Chief Executive Officer in writing by the applicant within twenty days after
the expiry of the period of sixty days but nothing herein shall be construed to
authorize any person to do anything in contravention of the Master Plan, lease
conditions, these Regulations and Planning and Development Directions issued
under Section 8 of the Uttar Pradesh Industrial Area Development Act, 1976.
(3) In case of refusal:-
(a) The Authorised Officer shall give
reasons and quote the relevant provision of the regulations which the plan
contravenes, as far as possible in the first instance itself and ensure that no
new objections are raised when they are re-submitted after compliance of
earlier objections.
(b) The Authority shall demolish the
unauthorised construction at the expense and cost of the
owner/lessee/sublessee. In case the owner/lessee/sublessee fails to pay the
above said cost, the same may be recovered from him as arrear of land revenue.
(4) Once the plans have been
scrutinised and objections, if any, have been pointed out, the applicant shall
modify the plans to comply with the objections raised and re-submit them. If
the objections remain unremoved for a period of sixty days, the permit shall be
refused and the plan shall stand rejected and fee submitted shall be forfeited.
(5) When Allottee submits the
application for seeking the occupancy certificate without actually completing
the building, inspection shall be done within 30 days. If during the inspection
for issue of completion certificate any building is found incomplete the
allottee will be penalised 50% of occupancy charges or Rs. 5000/- which ever is
more and his/her/their application for occupancy shall be rejected. On such
rejection of application the allottee will be required to apply afresh along
with penalty charges and time extension charges if required. The action against
all the concerned Technical person who has prepared the plan will be taken in
following steps
(i) First time - Warning to concerned
Technical person
(ii) Second time - black listed in
Authority for one year.
(iii) Third time - refer to Council of
Architecture/ITPI/MIC for cancellation of Registration.
Regulation - 14. Appeal against refusal or sanction with modification of a building permit.
Any applicant aggrieved by an order of refusal of a
building permit or its sanction under these regulations or directions, may
appeal to the Chairman of the Authority within sixty days from the date of
communication of such order. Such appeal shall be accompanied by a true copy of
the order appealed against, and receipt of appeal fee which shall be 50% of the
original plan fee. The decision of the Chairman on such appeal shall be final,
conclusive and binding. The chairman shall provide opportunity of hearing to
all concern parties with regard to the disputed map.
The appeal may be referred after sixty days of
communication of such order if within 30 days after the previous period of
sixty days he satisfies the chairman that he was prevented by sufficient causes
from not filing of appeal and not thereafter
Regulation - 15. Duration of validity of a building permit.
(1) A layout plan or building plan
permit sanctioned under these regulations shall remain valid for the period of
only 5 years. In case part completion has been taken on the plot, then also
validity of layout plan or building plan permit shall remain for 5 years. If
there is any alteration/revision in the plan, fresh revised plan permit shall
be required.
(2) Validity of a building permit for
a temporary structure shall be 5 years. Temporary structures shall be removed
immediately after the construction of building is over.
(3) After lapses of validity period
the applicant shall be liable to remove all such structures and completion
certificate shall not be granted without removal of such structures.
Regulation - 16. Additions or alterations during construction.
If any external additions or alterations from the
sanctioned plans are intended to be made, permission of the Chief Executive
Officer shall be obtained in writing before the proposed additions/alterations
are carried out. It shall be incumbent upon the applicant to whom a building
permit has been sanctioned to submit amended plans for such additions or
alterations. The provisions relating to an application for permit shall also
apply to such amended plans mutadis mutandis as given in Regulation 13 (2).
Regulation - 17. Cancellation of permit for building activity.
If at any time after the issuance of permit, the
Chief Executive Officer is satisfied that such permit was sanctioned in
consequence of any material misrepresentation or fraudulent statement contained
in the application given or the information furnished, the Chief Executive
Officer may, after giving an opportunity to the applicant of being heard,
cancel such permit and any work done thereunder shall be deemed to have been
done without permit. The Technical Person found responsible for the same shall
be blacklisted and debarred for 5 years from practicing in the notified area.
If the owner is found responsible for violations, action may be taken as per
lease deed.
Regulation - 18. Work to be carried out in full accordance of Zoning Regulations, Building Regulations and Directions.
Neither granting of the permit nor the approval of
drawings and specifications, nor inspection made by the Authority during such
erection shall in any way relieve the owner of such building from full
responsibility for carrying out the work in accordance with the requirements of
Zoning Regulations of Master Plan, these Regulations and/or Planning
Directions. In case any violations are found during construction or after obtaining
occupancy certificate the owner shall be required to rectify the same to the
satisfaction of the Authority within a period of 30 days from the time such
violations are intimated to the owner. In case the owner fails to comply, the
Authority shall ensure compliance and the expenditure incurred on doing so
shall be recovered from the owner before issue of occupancy certificate. In
case occupancy certificate has already been obtained, such expenditure if not
paid within stipulated time, shall be recovered from the owner, as arrears of
land revenue.
Regulation - 19. Documents at site.
The following documents shall be kept at site
during the construction of the building and for such a period thereafter as
required by the Authority: (i) A copy of building permit. (ii) Copy of approved
drawings. If the above documents are found missing for two consecutive visits
by the Authorized Officer of the Authority a penalty of Rs. 1000/- shall be
levied for each such lapse. In case building permit has not been granted and
applicant has applied for building permit then copy of receipt of documents
shall be kept (wherever applicable) at site.
Regulation - 20. Notice for issue of occupancy certificate.
Every owner shall have to submit a notice of
completion of the building to the Authority regarding completion of work
described in the building permit as per Appendix-9 accompanied by the documents
as per checklist annexed with Appendix-9.
20.1.1 Occupancy certificate
necessary for occupation-
No building erected, re-erected, shall be occupied
in whole or part until the issue of occupancy certificate by the Chief
Executive Officer in the Form given in Appendix -11. Provided that if the Chief
Executive Officer fails to issue the occupancy certificate or send any
intimation showing his inability to issue such certificate within 90 days of
the date of receipt of application for occupancy certificate an intimation to
this effect shall have to be sent to the Authority by the owner for occupying
the building.
In case objections are intimated by the Chief
Executive Officer or by an authorized officer showing inability to issue
occupancy certificate the owner shall take necessary action to remove the
objections. If the objections remain un-removed for a period of 6 months the
application for issue of occupancy certificate shall stand automatically
rejected. Thereafter the Chief Executive Officer shall take suitable action for
removal of unauthorised construction with fee. Thereafter, the applicant has to
apply afresh with fee for occupancy certificate and in such case time extension
shall not be required
20.1.2 Issue of occupancy
certificate regarding Multi Storey Buildings-
Without prejudice to the provision of regulation
20.1.1, In case of multi storey building the work shall also be subjected to
the inspection of the Chief Fire Officer, Uttar Pradesh Fire Service and the
occupancy certificate shall be issued by the Chief Executive Officer only after
the clearance from the Chief Fire Officer regarding the completion of work from
the fire protection point of view. Other certificates such as fees, structural
safety, water harvesting, etc also have to be submitted alongwith the
completion drawings
20.2 'Unsafe building' An unsafe building shall be considered to
constitute danger to public safety hygiene and sanitation and shall be restored
by repair or demolished or dealt with as otherwise directed by the Chief
Executive Officer of the Authority.
20.3 'Unauthorised development' In case of unauthorised development, the
Chief Executive Officer or an authorized officer by the Chief Executive Officer
shall
(i) Take suitable action which may
include demolition of unauthorized works, sealing of premises, prosecution and
criminal proceedings against the offenders in pursuance of relevant Acts in
force.
(ii) Take suitable action against the
technical person concerned.
20.4 'Temporary occupation'
Where the Chief Executive Officer on the
certificate of the technical personnel is satisfied that the temporary
occupation of a building or any portion thereof before its completion does not
adversely affect public welfare may permit temporary occupation in the Form
given in Appendix-11A of such building or portion thereof as the case may be,
for such period as he deems fit.
CHAPTER – III GENERAL REQUIREMENTS
SITE REQUIREMENTS
Regulation - 21. Distance from electric lines.
No verandah, balcony or like shall be allowed to be
erected or any additions or alterations made to any building within the
distance between the building and any overhead electric supply line as
indicated below.
|
Horizontally
|
Vertically
|
|
|
(a) Low and medium voltage
|
2.4 metres
|
1.2 metres
|
|
(b) High voltage lines upto and including 33000
volts
|
3.7 metres
|
1.8 metres
|
|
(c) Extra high voltage lines
|
3.7m + (0.305 metres
for every additional 33000 volts)
|
1.8 mtrs+ (0. 305
metres for every additional 33000 volts)
|
Regulation - 22. Site and land use pattern.
Notwithstanding anything contained in these
regulations, no building permit on any site shall be sanctioned if;-
(i) the proposed land use does not correspond
to the land use in the Development Plan/Master Plan/Layout Plan
(ii) the construction of any building
is for public worship, which in the opinion of the Authority will affect the
religious feelings of any class or persons in the vicinity thereof.
(iii) the use of building or place will
be a source of annoyance to, or injurious to the health of the inhabitants of
the neighbourhood.
Regulation - 23. Means of Access.
No building shall be erected so as to deprive any
other building of the means of access.
Regulation - 24. Ground coverage, Floor Area Ratio, Height and Setbacks.
24.1 Residential Buildings on
plots (other than flatted group housing)
(1) Ground coverage, Floor Area
Ratio, height and setbacks shall be as per Table-I appended to these
regulations. However, the set back shall be applicable as per regulations
prevailing at the time of initial allotment of sector.
(2) Other provisions:
(i) The directions of side, rear set
back and gate shall be as per the Setback/Layout Plan and directions prepared
by the Authority from time to time.
(ii) In case of plots being
amalgamated with the approval of the Authority, the set back lines in front and
adjoining property are to be followed as per Setback Plan.
(iii) Subdivision of individual
residential plot or building constructed on it shall not be allowed.
(iv) Only two dwelling units and a
servant quarter shall be allowed upto a plot size of 100sq mtrs. For plots
above 100 sqmtrs and upto 500 sqmtrs maximum three dwelling units shall be
allowed. For plots above 500 sq mtrs. maximum four dwelling units shall be
allowed. In density calculation 4.5 person per dwelling unit shall be
considered in all kind of residential plots. Each servant quarter shall be
counted as half dwelling unit.
(v) Stilt parking shall be allowed
upto maximum height of 2.4 mtrs upto bottom of beam free from FAR for plot size
of 112 sq mtrs and above. However, in case stilt is not provided, parking may
be allowed in the setbacks.
(vi) No construction of any kind shall
be permitted beyond the building envelope (on set backs) except
(a) A chajja (projection) of maximum
width of 0.75 metres at lintel or roof level. No construction of any type shall
be permitted over such projections.
(b) Underground water tanks with top
flush with the adjoining ground level.
(c) In plots of 200 square metre and
above, if required, a temporary guard room of porta cabin 1.5 metre x 1.5 metre
shall be permitted after approval by the Authority.
(d) Canopy projections of 4.5 metre
X. 2.4 metre in front or side set backs (maximum 2 numbers) in plots where
front set back is 4.5 metre or more and only one such canopy in side set back
where front set back is less than 4.5 metre. No construction of any type shall
be permitted over the canopy projection. The canopy may be supported by
circular column of maximum 30 centimetres diametre or rectangular columns of 30
centimetres x 30 centimetre size.
(e) Open Plinth steps:
(i) Open plinth steps and plinth ramp
in front and rear setback.
(ii) Open plinth steps and plinth
ramps beyond a depth of 6 mtrs in side setback.
(f) In case of corner plots upto 200
square metre category, load bearing columns max size 300 milimetre X 300
milimetre in side setback maximum 2 numbers may be permitted.
(g) Other features as mentioned in
Table 3.
(h) Open ramps for movement of
vehicles in side setback only.
(i) Balcony upto 1.5 m width (upto
1.0 m width where setback is less than 3.0 m)
(j) No enclousure of any type shall
be allowed on the balcony, neither shall be compoundable.
(k) The inner courtyard can be
covered by a temporary coverage, at a height of 1.5 mtrs. above roof level. If
covered at roof level, it shall not be permissible.
(l) The internal changes within the
building envelope are permissible without any revision submission.
(vii) FAR shall also include
(i) Mezzanine
(ii) Pergola shall be counted towards
Floor Area Ratio calculation if closed from three or more than three sides.
(viii) Floor Area Ratio shall not
include -
(i) A cantilever projection (in
setbacks) of a width of 0.75 metre at any level. No construction of any type or
any material shall be permitted over projections other than mentioned herewith.
(ii) Canopy projections of 4.5 metre X
2.4 metre in front or side set back (maximum 2 numbers), in plots where front
set back is 4.5 metre or more and only one such canopy in side setback where
front setback is less than 4.5 metres.
(iii) Basement, (only single basement)
equivalent to ground coverage shall be permitted, if used for parking, services
and storage.
(iv) Stilt area of non-habitable
height proposed to be used for parking, landscaping etc.
(v) Loft upto 1.5 metre height
(vi) Other features as mentioned in
Table 3.
(vii) Open ramps for movement of
vehicles in side setback only.
(viii) Balconies (upto 1.50 mtrs. width,
If Balcony of more than 1.50 mtrs. width is proposed, then 1/4th of its area
shall be counted in FAR), Cupboard (0.60m wide), Staircase, Lift, Mumty for
staircase, and Bay windows.
(ix) Basement:
(i) Basement area shall not exceed
beyond building envelope.
(ii) The height of any basement shall
be maximum 1.5 metre from bottom of the slab above the top level of the
external drain. The maximum height of the basement from floor to ceiling shall
be 4.5 metres.
(iii) Basement shall be allowed upto a
distance of 2.0 mtrs. from the adjacent plot on the basis of structure
stability certificate.
(x) Minimum requirement for
sanction/completion: 40 sqm or 50 percent of maximum permissible ground
coverage(whichever is more) with provisions of a functional toilet/bath and
kitchen Provision of following items in building shall be mandatory for issue
of occupancy certificate.
(i) Flooring;
(ii) Electrical wiring whereas
electrical fittings shall not be mandatory.
(iii) Plumbing and fittings in at least
one toilet and kitchen
(iv) Trees as per Table no. 6 or
direction issued from time to time which ever is higher;
(v) Number plate;
(vi) Boundary wall shall be mandatory.
(vii) Internal and external finishing
(Plastering and transparentwashing shall not be mandatory);
(viii) House shall be lockable i.e. all external
doors and windows shall have to be provided with grill provided in the windows
then fixing of glasses in the windows panes shall not be mandatory;
(ix) No violation of Building
Regulations, Zonal Plan Regulations and Master Plan should be there in the
building at the time of issue of occupancy certificate.
24.2 GROUP HOUSING (Flatted and
cluster type)
(I) Minimum Plot Area- 2000 square
metre. However, the Authority may revise this limit by recording the reason.
(II) Maximum permissible -
|
(i)
|
Ground coverage
|
35 percent up to 40000 sq mtrs and 40% above
40000 sq. mtrs.
|
|
(ii)
|
Floor Area Ratio
|
3.00
|
|
(iii)
|
Height
|
No limit. For buildings above 30 metres in
height, clearance from Airport Authority shall have to be taken.
|
|
(iv)
|
Density(Family size 4.5)
|
As mentioned in the sector Layout Plan or decided
by the Authority for a particular scheme.
|
24.2.1 Other Provisions:
(1) No construction of any kind shall
be permitted beyond the building envelope (on setbacks) except
(i) A Chajja (projection) of maximum
width of 0.75 metre at lintel or roof level. No construction of any type or any
material shall be permitted over projections other than mentioned herewith.
(ii) Underground water tanks with top
flush with the adjoining ground level.
(iii) Watchman Shelters and Watch
Towers with following provisions:
(iv) No projection of watchman
shelters and watch towers shall be allowed outside the plot line.
(v) Maximum height of watchman
shelter shall be 4 metres and for watch towers 15 metres. Total area, as
mentioned below, under such shelters shall be split up in desired number of
watch man shelter and watch towers as follows:
|
Sr.
No.
|
Plot Size
|
Total area for watchman shelter and watch tower
|
Maximum area under each
watchman shelter
|
Maximum area under
each watch tower
|
|
1
|
Up to 0.5 acres
|
15 square metres
|
15 square metres
|
5 square metres
|
|
2
|
Above 0.5 acres up to 10 acres
|
30 square metres
|
24 square metres
|
5 square metres
|
|
3
|
Above 10 acres up to 25 acres
|
45 square metres
|
24 square metres
|
5 square metres
|
|
4
|
Above 25 acres up to 50 acres
|
60 square metres
|
24 square metres
|
5 square metres
|
|
5
|
Above 50 acres for an additional 50 acres
|
An additional 10 square metres and part thereof
|
24 square metres
|
5 square metres
|
(vi) The following features shall be
permitted after leaving minimum 6 mtrs. open corridor for fire tenders.
(a) Metre room as per norms of
Electricity Authority.
(b) Open transformers without any
permanent enclosure keeping in view the necessary safety requirements.
(c) Other features as mentioned in
Table 3
(d) Rockery, well and well
structures, water pool, swimming pool (if uncovered), uncovered platform around
tree, tank, fountain, bench, chabutra with open top and unenclosed by side
walls, compound wall, gate, slide swing, culverts on drains.
(e) Any other feature, primarily
ornamental in nature, not enclosing or covering space of commercial use may be
permitted by the Chief Executive Officer on case to case basis.
(f) Open generator set, filtration
plant, Electrical distribution equipments, feeder pillars, telephone
distribution equipments may be permitted in open setback as a service utility
provided after leaving clear space for fire tender.
(2) Floor Area Ratio shall include
(i) Mezzanine
(ii) The shafts provided for lifts
shall be taken for covered area calculations only on one floor and included in
ground coverage.
(iii) Pergola, shall be counted towards
Floor Area Ratio if closed from three or more than three sides.
(iv) Metre room as per Electricity
Authority norms.
(3) Floor Area Ratio shall not
include:
(i) A cantilever projection at any
level (in setbacks) of a width of 0.75 metre. No construction of any type or
any material shall be permitted over projections.
(ii) Basement(s), shall be permissible
within the setback line on each floor. However maximum permissible area under
basement shall be limited up to:
(a) Basement area, if used for
services, storage etc. then maximum area under such facilities shall be
equivalent to maximum permissible ground coverage.
(b) Basement area/Podium parking as
defined in parking table, if used for parking, then area equivalent to parking
requirement shall be permitted.
(c) In plots bigger than 10000 sq
mtrs. The basement shall be allowed in setback area after leaving a minimum
setback of 6.0 mtrs.
(iii) Basement, if put to any use other
than mentioned above, shall be included in the FAR of the building.
(iv) Stilt area of non-habitable
height 2.40 metres from bottom of beam proposed to be used for parking,
landscaping etc.
(v) Balconies upto 1.5 metre width
free from FAR (in case it is more than 1.5 m, 1/2 of area beyond 1.5 m shall be
included in FAR) may be projected in open setbacks provided 6 mtrs. clear space
is available for fire tender movement.
(vi) Other features as mentioned in
Table 3.
(vii) Rockery, well and well
structures, water pool, swimming pool (if uncovered), uncovered platform around
tree, tank, fountain, bench, chabutra with open top and unenclosed by side
walls, compound wall, gate, slide, swing, uncovered staircase (unenclosed and
uncovered on three sides except for 0.9 metre high railing/wall and open to
sky), overhead tanks on top of buildings, open shafts, culverts on drains.
(viii) Open ramps with no area enclosed
below it of usable height. If used for approach to the entrance of the
building, then the height as per requirement may be considered. The space under
the ramp shall not be used for any commercial purpose, however it can be
landscaped with approval of the Chief Executive Officer on case to case basis.
(ix) Atrium shall be kept free from
FAR and ground coverage. In case any commercial activity is proposed in Atrium
or any saleable area or any other structure which is counted in FAR &
ground coverage, its respective area shall be added in total FAR & ground
coverage.
(x) Any other feature purely
ornamental in nature and not enclosing or covering space of commercial use may
be permitted by the Chief Executive Officer on case to case basis.
(xi) Additional 5% of the plot area as
ground coverage will be allowed for dedicated multi level parking in plots
bigger than 10000 sq mtrs.
(xii) In multistorey buildings service
floor may be allowed after 4 floors. Maximum of 3 service floors may be allowed
in a building. Service floor shall not be counted in FAR and maximum height of
service floor shall be 2.40 mtrs. from floor to bottom of the beam.
(4) All the common facilities
prescribed below will have to be provided and shall be counted in the
prescribed FAR of Group Housing Shops and community facilities as per
population norms as specified in the earlier lease deed. In case of plots where
minimum population required for provision of convenient shopping is not
achieved then:-
(a) Area for shopping and commercial
activities equivalent to 1.0 percent permissible FAR of the plot area shall be
allowed.
(b) Minimum four kiosks of 4 sq.m of
carpet area and two shops of 10 sqm carpet area shall be provided mandatorily.
(c) Maximum height of shops and
kiosks shall be 4.0 metre from floor to ceiling.
(d) However shops may be allowed as
integral part of Group housing building on the ground floor.
(5) 15% of prescribed FAR shall be
added towards common areas, which shall include the following built structures.
The structures on ground will be counted in Ground Coverage
(1) Canopy projections of area as
mentioned in table 4, no construction of any type shall be permitted over the
canopy. Canopy, if cantilevered and no structure on it having a size of 2.4m x
4.5m shall not be counted in Ground Coverage.
(2) Loft up to maximum height of 1.5
metres.
(3) Air-conditioning plant,
electrical installation, generator room, water works, water tank etc.
(4) Watchmen/Security shelters and
watch towers
(5) Garbage shafts, lift shafts and
10 sq mtrs lobby infront of each lift (excluding area of corridor beyond the
lift).
(6) Fire escape staircases
(7) Toilet blocks for visitors,
drivers, guards etc on ground floor only.
(8) Mumty, machine room for lifts.
(9) Cupboards upto a depth of 0.60
mtr. and 1.80 mtrs. in length.
(10) Bay window upto a depth of 0.60
mtr. and 2.0 mtrs length.
(11) Refuge area as per definition for
fire evacuation in National Building Code, 2005.
(12) Sewage treatment plant, water
treatment plant, garbage collection centre, Electric sub-station, service
ducts, community hall, religious building, milk and vegetable booth, school
& cr?che.
(13) Covered walkways and pathways.
(14) Any other utilities and
facilities as decided by the Chief Executive Officer depending upon its
requirement.
(6) Distance between two adjacent
building blocks
Distance between two adjacent building blocks shall
be minimum 6 mtrs. to 16 mtrs, depending on the height of blocks. For building
height up to 18 mtrs., the spacing shall be 6 mtrs. and thereafter the spacing
shall be increased by 1 metre for every addition of 3 mtrs. in height of
building subject to a maximum spacing of 16 mtrs. as per National Building Code
-2005. If the blocks have dead-end sides facing each other, than the spacing
shall be maximum 9 mtrs. instead of 16 mtrs. Moreover, the allottee may provide
or propose more than 16 mtrs space between two blocks.
(7) The Authority shall have a right
to impose such restriction and limitations as to the number of storey and
extent of height of the building as he considers fit where protected areas,
ancient or historical monuments lie within a radius of one and half kilo metre
from the boundary line of such buildings by recording the reasons.
(8) In density calculation each
servant quarter will be reckoned as half dwelling unit. (standard size of the
family for a dwelling unit for density purpose is 4.5 persons)
(9) A group housing shall conform to
the provisions of the Sector Plan and Zonal Development Plan or scheme (if any)
of the area, in terms of setbacks, ground coverage, Floor Area Ratio and height
restrictions.
(10) The provisions contained in this
regulation shall not apply to housing for economically weaker sections and low
income group schemes undertaken by the State Government, Authority or any other
public body approved in this behalf by the State Government. The Authority may
decide the norms for setback, Ground coverage F.A.R. height, density, parking
etc. for specific projects of these groups depending upon the size of plot,
width of Road, availability of infrastructure, etc. by recording the reasons.
(11) The internal height of the
basement (floor to ceiling) shall be minimum 2.4 mtrrs from bottom of beam and
maximum 4.5 metres, except wherever height of equipments such as electric
generator, air conditioner, fire hydrant etc is more than 4.5 metres,
additional height equivalent to height of equipments may be permitted. In case
of Automatic/semi automatic/mechanised parking facility also more than 4.5
mtrs, additional height may be allowed by the Chief Executive Officer depending
upon the technology and requirement of space.
(12) The height of basement shall be
maximum 1.5 metres upto bottom of the slab above the top of the drain. In case
the basement is flush with the ground level adequate light and ventilation
shall be ensured.
(13) Toilet block for visitors,
drivers etc. comprising of minimum a water closet, a bath and 2 urinals shall
be provided on the ground floor.
(14) In case of group housing having
more than two storey, steps must be taken to ensure water at higher floors. For
this purpose booster pumps and overhead tanks may be installed.
(15) At least one of the lifts
provided shall be of the specification of goods lift.
(16) Minimum requirement for
sanction/completion: Minimum covered area required for completion shall be as
per lease deed or Memorandum of Understanding or as follows:-
|
S. NO.
|
SIZE OF PLOT(SQ. MTRS.)
|
MINIMUM BUILT UP AREA(AS %OF TOTAL PERMISSIBLE
FAR)
|
|
1.
|
Upto 4000 Sq. Mtrs.
|
50%
|
|
2.
|
Exceeding 4000 Sq. Mtrs. but not exceeding 10000
Sq. Mtrs.
|
40%
|
|
3.
|
Exceeding 10000 Sq. Mtrs. but not exceeding 20000
Sq. Mtrs.
|
35%
|
|
4.
|
Exceeding 20000 Sq. Mtrs. but not exceeding
100000 Sq. Mtrs.
|
30%
|
|
5.
|
Exceeding 100000 Sq. Mtrs. but not exceeding
200000 Sq. Mtrs.
|
25%
|
|
6.
|
Exceeding 200000 Sq. Mtrs. but not exceeding
400000 Sq. Mtrs.
|
20%
|
|
7.
|
Above 400000 Sq. Mtrs.
|
15%
|
Note:
(i) No further time extension shall
be required if the completion has been taken by the allottee as per table
mentioned above. The above mentioned completion requirement shall be applicable
in all allotments. In the old allotments, the provisions of project report or
lease deed or previous options may be followed.
(ii) However validity of plans may be
granted to the allottee in multiples of 5 years after taking completion of
minimum area.
(iii) In all the projects of 40
hactares and above, block wise temporary Occupancy may be allowed subject to a
minimum of 1,00,000 sqm built up area, the building completed with all
mandatory provisions of services and the allottee shall segregate these blocks
for the purpose of security during construction period.
(17) Provision of following item in
building shall be mandatory for issue of completion certificate:
(i) Flooring;/i.e. hard surface and
completely finished floors for common areas or/and public use areas.
(ii) Electrical wiring;
(iii) Plumbing work to be complete.
(iv) Parking and landscaping as per
Table no. 5 and Table no. 6 respectively or as per directions issued from time
to time whichever is higher;
(v) Number plate and illumination
board as per direction amended or direction issued from time-to-time;
(vi) Internal and external finishing
(Plastering may not be mandatory);
(vii) Boundary wall and gates shall be
mandatory;
(viii) Buildings shall be lockable i.e.
all external doors and windows shall be provided. In case grill is provided in
the windows the fixing of glass in the windows pane shall not be mandatory;
(ix) No violation should be there in
the overall building or site at the time of issue of occupancy certificate;
(x) Any other special provision as
mentioned in the lease deed;
(xi) In case of completion of whole
project, all temporary structures to be removed. In case if any special clause
is mentioned in the lease deed or Memorandum of Understanding then the
requirement mentioned in the same shall be applicable.
24.3 Industrial Buildings:
Ground coverage, Floor Area Ratio and height
|
S.No.
|
Plot Area (square metre)
|
Maximum Ground coverage (%)
|
Maximum Floor Area Ratio
|
Maximum Height in mtrs
|
|
1.
|
Up to 1000
|
60
|
1.50
|
18
|
|
2.
|
Above 1000 but not exceeding 12000
|
60
|
1.30
|
24
|
|
3.
|
Above 12000
|
55
|
1.00
|
No Limit
|
|
4.
|
Flatted Factories
|
35
|
1.40
|
24
|
24.3.1 Other Provisions:
(1) No construction of any kind shall
be permitted beyond the building envelope (on setbacks) except
(i) No construction of any type or
any material shall be permitted over projections other than mentioned herewith.
(ii) Underground water tanks with top
flush with the adjoining ground level.
(iii) Watchman Shelters and Watch
Towers with following provisions:
(iv) No projection of watchman
shelters and watch towers shall be allowed outside the plot line.
(v) Maximum height of watchman
shelter shall be 4 metres and for watch towers 15 metres. Total area, as
mentioned below, under such shelters shall be split up in desired number of
watch man shelter and watch towers as follows:
|
Sr. No.
|
Plot Size
|
Total area for watchman shelter and watch tower
|
Maximum area under each watchman shelter
|
Maximum area under each watch tower
|
|
1
|
Upto 0.5 acres
|
15 square metre
|
15 square metre
|
5 square metre
|
|
2
|
Above 0.5 acres upto 10 acres
|
30 square metre
|
24 square metre
|
5 square metre
|
|
3
|
Above 10 acres upto 25 acres
|
45 square metre
|
24 square metre
|
5 square metre
|
|
4
|
Above 25 acres upto 50 acres
|
60 square metre
|
24 square metre
|
5 square metre
|
|
5
|
Above 50 acres for an additional 50 acres
|
An additional 10 square metre and part thereof
|
24 square metre
|
5 square metre
|
(vi) The following features shall be
permitted after leaving minimum 6 mtrs. open corridor for fire tenders.
(a) Metre room as per norms of
Electricity Authority..
(b) Open transformers without any
permanent enclosure keeping in view the necessary safety requirements.
(c) Other features as mentioned in
Table 3
(d) Rockery, well and well
structures, water pool, swimming pool (if uncovered), uncovered platform around
tree, tank, fountain, bench, chabutra with open top and unenclosed by side
walls, compound wall, gate, slide swing, culverts on drains.
(e) Any other feature, primarily
ornamental in nature, not enclosing or covering space of commercial use may be
permitted by the Chief Executive Officer on case to case basis.
(f) Open generator set, filtration
plant, Electrical distribution equipments, feeder pillars, telephone
distribution equipments may be permitted in open setback as a service utility
provided after leaving clear space for fire tender.
(2) Floor Area Ratio shall include
(i) Mezzanine
(ii) The shafts provided for lifts
shall be taken for covered area calculations only on one floor and included in
ground coverage.
(iii) Pergola, shall be counted towards
Floor Area Ratio if closed from three or more than three sides.
(iv) Metre room as per Electricity
Authority norms.
(3) Floor Area Ratio shall not
include:
(i) A cantilever projection at any
level (in setbacks) of a width of 0.75 metre. No construction of any type or
any material shall be permitted over projections.
(ii) Basement(s), shall be permissible
within the setback line on each floor. However maximum permissible area under
basement shall be limited up to:
(a) Basement area, if used for
services, storage etc. then maximum area under such facilities shall be
equivalent to maximum permissible ground coverage.
(b) Basement area/Podium parking as
defined in parking table, if used for parking, then area equivalent to parking
requirement shall be permitted.
(c) In plots bigger than 10000 sq
mtrs. The basement shall be allowed in setback area after leaving a minimum
setback of 6.0 mtrs.
(iii) Basement, if put to any use other
than mentioned above, shall be included in the FAR of the building.
(iv) Stilt area of non-habitable
height 2.40 metres from bottom of beam proposed to be used for parking,
landscaping etc.
(v) Balconies (Upto 1.5 metres width
free) from FAR may be projected in open setbacks provided 6 mtrs. clear space
is available for fire tender movement.
(vi) Other features as mentioned in
Table 3.
(vii) Rockery, well and well
structures, water pool, swimming pool (if uncovered), uncovered platform around
tree, tank, fountain, bench, chabutra with open top and unenclosed by side
walls, compound wall, gate, slide, swing, uncovered staircase (unenclosed and
uncovered on three sides except for 0.9 metre high railing/wall and open to
sky), overhead tanks on top of buildings, open shafts, culverts on drains.
(viii) Open ramps with no area enclosed
below it of usable height. If used for approach to the entrance of the
building, then the height as per requirement may be considered. The space under
the ramp shall not be used for any commercial purpose. However it can be
landscaped with approval of the Chief Executive Officer on case to case basis.
(ix) Atrium shall be kept free from
FAR and ground coverage. In case any commercial activity is proposed in Atrium
or any saleable area or any other structure which is counted in FAR &
ground coverage, its respective area shall be added in total FAR & ground
coverage.
(x) Any other feature purely
ornamental in nature and not enclosing or covering space of commercial use may
be permitted by the Chief Executive Officer on case to case basis.
(xi) Additional 5% of the plot area as
ground coverage will be allowed for dedicated multi level parking in plots
bigger than 10000 sq mtrs (excluding green areas).
(xii) In multistorey buildings service
floor may be allowed after 4 floors. Maximum of 3 service floors may be allowed
in a building. Service floor shall not be counted in FAR and maximum height of
service floor shall be 2.40 mtrs. from floor to bottom of the beam.
(4) 15% of prescribed FAR shall be
added towards common areas, which shall include the following built structures.
The structures on ground will be counted in Ground Coverage
(1) Canopy projections of area as
mentioned in table 4, no construction of any type shall be permitted over the
canopy. Canopy, if cantilevered and no structure on it having a size of 2.4m x
4.5m shall not be counted in Ground Coverage.
(2) Loft up to maximum height of 1.5
metre.
(3) Air-conditioning plant,
electrical installation, generator room, water works, water tank etc.
(4) Watchmen/Security shelters and
watch towers
(5) Garbage shafts, lift shafts and
10 sq mtr lobby infront of each lift.
(6) Fire escape staircases
(7) Toilet blocks for visitors,
drivers, guards etc on ground floor only.
(8) Mumty, machine room for lifts.
(9) Cupboards upto a depth of 0.60
mtr and 1.80 mtrs. in length.
(10) Refuge area as per definition for
fire evacuation in NATIONAL BUILDING CODE, 2005
(11) Sewage treatment plant, water
treatment plant, garbage collection centre, Electric sub-station, service
ducts.
(12) Covered walkways and pathways.
(13) Any other utilities and
facilities as decided by the Chief Executive Officer depending upon its requirement.
(5) Distance between two adjacent
building blocks
Distance between two adjacent building blocks shall
be minimum 6 mtrs. to 16 mtrs, depending on the height of blocks. For building
height up to 18 mtrs., the spacing shall be 6 mtrs. and thereafter the spacing
shall be increased by 1 metre for every addition of 3 mtrs. in height of
building subject to a maximum spacing of 16 mtrs. as per NATIONAL BUILDING
CODE, 2005. If the blocks have dead-end sides facing each other, than the
spacing shall be maximum 9 mtrs. instead of 16 mtrs. Moreover, the allottee may
provide or propose more than 16 mtrs space between two blocks.
(6) The Authority shall have a right
to impose such restriction and limitations as to the number of storey and
extent of height of the building as he considers fit where protected areas,
ancient or historical monuments lie within a radius of one and half kilo metre
from the boundary line of such buildings by recording the reasons.
(7) The internal height of the
basement (floor to ceiling) shall be minimum 2.4 mtrs from bottom of beam and
maximum 4.5 metre. Except wherever height of equipments such as electric
generator, air conditioner, fire hydrant etc. is more than 4.5 metre,
additional height equivalent to height of equipments may be permitted. In case
of Automatic/semi automatic/mechanised parking facility also more than 4.5
mtrs, additional height may be allowed by the Chief Executive Officer depending
upon the technology and requirement of space.
(8) The height of basement shall be
maximum 1.5 metres upto bottom of the slab above the top of the drain. In case
the basement is flush with the ground level adequate light and ventilation
shall be ensured.
(9) Toilet block for visitors,
drivers etc. comprising of minimum a water closet, a bath and 2 urinals shall
be provided on the ground floor.
(10) At least one of the lifts
provided shall be of the specification of goods lift.
(11) Minimum requirement for
sanction/completion: Minimum covered area required for completion shall be as
per lease deed or Memorandum of Understanding or as follows:-
|
S. NO.
|
SIZE OF PLOT (SQ. MTRS.)
|
MINIMUM BUILT UP AREA (AS %OF TOTAL PERMISSIBLE
FAR)
|
|
1.
|
Up to 4000 Sq. Mtrs.
|
50%
|
|
2.
|
Exceeding 4000 Sq. Mtrs. but not exceeding 10000
Sq. Mtrs.
|
40%
|
|
3.
|
Exceeding 10000 Sq. Mtrs. but not exceeding 20000
Sq. Mtrs.
|
35%
|
|
4.
|
Exceeding 20000 Sq. Mtrs. but not exceeding
100000 Sq. Mtrs.
|
30%
|
|
5.
|
Exceeding 100000 Sq. Mtrs. but not exceeding
200000 Sq. Mtrs.
|
25%
|
|
6.
|
Exceeding 200000 Sq. Mtrs. but not exceeding
400000 Sq. Mtrs.
|
20%
|
|
7.
|
Above 400000 Sq. Mtrs.
|
15%
|
Note:
(i) No further time extension shall
be required if the completion has been taken by the allottee as per table
mentioned above. The above mentioned completion requirement shall be applicable
in all allotments. In the old allotments, the provisions of project report or
lease deed or previous options may be followed.
(ii) However validity of plans may be
granted to the allottee in multiples of 5 years after taking completion of
minimum area,
(iii) In all the projects of 40
hactares and above, block wise temporary Occupancy may be allowed subject to a
minimum of 1,00,000 sqm built up area, the building completed with all
mandatory provisions of services and the allottee shall segregate these blocks
for the purpose of security during construction period.
(12) Provision of following item in
building shall be mandatory for issue of completion certificate:
(i) Flooring;/i.e. hard surface and
completely finished floors for common areas or/and public use areas.
(ii) Electrical wiring;
(iii) Plumbing work to be complete.
(iv) Parking and landscaping as per
Table no. 5 and Table no. 6 respectively or as per directions issued from time
to time whichever is higher;
(v) Number plate and illumination
board as per direction amended or direction issued from time-to-time;
(vi) Internal and external finishing
(Plastering may not be mandatory);
(vii) Boundary wall and gates shall be
mandatory;
(viii) Buildings shall be lockable i.e.
all external doors and windows shall be provided. In case grill is provided in
the windows the fixing of glass in the windows pane shall not be mandatory;
(ix) No violation should be there in
the overall building or site at the time of issue of occupancy certificate;
(x) Any other special provision as
mentioned in the lease deed;
(xi) In case of completion of whole
project, all temporary structures to be removed. In case if any special clause
is mentioned in the lease deed or Memorandum of Understanding then the
requirement mentioned in the same shall be applicable.
24.4 COMMERCIAL BUILDINGS
Ground coverage, Floor Area Ratio and height
|
Sl. No.
|
Use
|
Maximum ground coverage
|
Maximum FAR
|
Maximum height in metres
|
|
1
|
Convenient Shopping Centre
|
40%
|
2.00
|
24.0
|
|
2
|
Sector Shopping
|
40%
|
2.00
|
24.0
|
|
3
|
Sub District Centre, Shopping/commercial uses
along MP roads and other Master Plan level Shopping/commercial Centres
|
30%
|
4.00
|
No limit
|
|
4.
|
Hotel
|
30%
|
3.00
|
No limit
|
|
5
|
Banks
|
30%
|
1.50
|
No limit
|
|
6
|
Cinema/Multiplex/Cineplex
|
30%
|
As per govt. policy
|
No limit
|
|
7.
|
Warehousing/Godowns
|
60%
|
1.50
|
No limit
|
24.4.1 Other Provisions:
(1) No construction of any kind shall
be permitted beyond the building envelope (on setbacks) except
(i) A Chajja (projection) of maximum
width of 0.75 metre at lintel or roof level. No construction of any type or any
material shall be permitted over projections other than mentioned herewith.
(ii) Underground water tanks with top
flush with the adjoining ground level.
(iii) Watchman Shelters and Watch
Towers with following provisions:
(iv) No projection of watchman
shelters and watch towers shall be allowed outside the plot line.
(v) Maximum height of watchman
shelter shall be 4 metres and for watch towers 15 metres. Total area, as
mentioned below, under such shelters shall be split up in desired number of
watch man shelter and watch towers as follows:
|
Sr. No.
|
Plot Size
|
Total area for watchman shelter and watch tower
|
Maximum area under each watchman shelter
|
Maximum area under each watch tower
|
|
1
|
Upto 0.5 acres
|
15 square metre
|
15 square metre
|
5 square metre
|
|
2
|
Above 0.5 acres upto 10 acres
|
30 square metre
|
24 square metre
|
5 square metre
|
|
3
|
Above 10 acres upto 25 acres
|
45 square metre
|
24 square metre
|
5 square metre
|
|
4
|
Above 25 acres upto 50 acres
|
60 square metre
|
24 square metre
|
5 square metre
|
|
5
|
Above 50 acres for an additional 50 acres
|
An additional 10 square metre and part thereof
|
24 square metre
|
5 square metre
|
(vi) The following features shall be
permitted after leaving minimum 6 mtrs. open corridor for fire tenders.
(a) Metre room as per norms of
Electricity Authority..
(b) Open transformers without any
permanent enclosure keeping in view the necessary safety requirements.
(c) Other features as mentioned in
Table 3
(d) Rockery, well and well
structures, water pool, swimming pool (if uncovered), uncovered platform around
tree, tank, fountain, bench, chabutra with open top and unenclosed by side
walls, compound wall, gate, slide swing, culverts on drains.
(e) Any other feature, primarily
ornamental in nature, not enclosing or covering space of commercial use may be
permitted by the Chief Executive Officer on case to case basis.
(f) Open generator set, filtration
plant, Electrical distribution equipments, feeder pillars, telephone
distribution equipments may be permitted in open setback as a service utility
provided after leaving clear space for fire tender.
(2) Floor Area Ratio shall include
(i) Mezzanine
(ii) The shafts provided for lifts
shall be taken for covered area calculations only on one floor and included in
ground coverage.
(iii) Pergola, shall be counted towards
Floor Area Ratio if closed from three or more than three sides.
(iv) Metre room as per Electricity
Authority norms.
(3) Floor Area Ratio shall not
include:
(i) A cantilever projection at any
level (in setbacks) of a width of 0.75 metre. No construction of any type or
any material shall be permitted over projections.
(ii) Basement(s) shall be permissible
within the setback line on each floor. However maximum permissible area under
basement shall be limited up to:
(a) Basement area, if used for
services, storage etc. then maximum area under such facilities shall be
equivalent to maximum permissible ground coverage.
(b) Basement area/Podium parking as
defined in parking table, if used for parking, then area equivalent to parking
requirement shall be permitted.
(c) In plots bigger than 10000 sq
mtrs. The basement shall be allowed in setback area after leaving a minimum
setback of 6.0 mtrs.
(iii) Basement, if put to any use other
than mentioned above, shall be included in the FAR of the building.
(iv) Stilt area of non-habitable
height 2.40 metres from bottom of beam proposed to be used for parking,
landscaping etc.
(v) Balconies (upto 1.5 metre width)
free from FAR may be projected in open setbacks provided 6 mtrs. clear space is
available for fire tender movement.
(vi) Other features as mentioned in
Table 3.
(vii) Rockery, well and well
structures, water pool, swimming pool (if uncovered), uncovered platform around
tree, tank, fountain, bench, chabutra with open top and unenclosed by side
walls, compound wall, gate, slide, swing, uncovered staircase (unenclosed and
uncovered on three sides except for 0.9 metre hightailing/wall and open to
sky), overhead tanks on top of buildings, open shafts, culverts on drains.
(viii) Open ramps with no area enclosed
below it of usable height. If used for approach to the entrance of the
building, then the height as per requirement may be considered. The space under
the ramp shall not be used for any commercial purpose, however it can be
landscaped with approval of the Chief Executive Officer on case to case basis.
(ix) Atrium shall be kept free from
FAR and ground coverage. In case any commercial activity is proposed in Atrium
or any saleable area or any other structure which is counted in FAR &
ground coverage, its respective area shall be added in total FAR & ground
coverage.
(x) Any other feature purely
ornamental in nature and not enclosing or covering space of commercial use may
be permitted by the Chief Executive Officer on case to case basis.
(xi) Additional 5% of the plot area as
ground coverage will be allowed for dedicated multi level parking in plots
bigger than 10000 sq mtrs (excluding green areas).
(xii) In multistorey buildings service
floor, may be allowed after 4 floors. Maximum of 3 service floors may be
allowed in a building. Service floor shall not be counted in FAR and maximum
height of service floor shall be 2.40 mtrs. from floor to bottom of the beam.
(4) 15% of prescribed FAR shall be
added towards common areas, which shall include the following built structures.
The structures on ground will be counted in Ground Coverage
(1) Canopy projections of area as
mentioned in table 4, no construction of any type shall be permitted over the
canopy. Canopy, if cantilevered and no structure on it having a size of 2.4m x
4.5m shall not be counted in Ground Coverage.
(2) Loft up to maximum height of 1.5
metre.
(3) Air-conditioning plant,
electrical installation, generator room, water works, water tank etc.
(4) Watchmen/Security shelters and
watch towers
(5) Garbage shafts, lift shafts and
10 sq mtr lobby infront of each lift (excluding area of corridor beyond the
lift).
(6) Fire escape staircases
(7) Toilet blocks for visitors,
drivers, guards etc on ground floor only.
(8) Mumty, machine room for lifts.
(9) Cupboards upto a depth of 0.60
mtr and 1.80 mtrs. in length.
(10) Refuge area as per definition for
fire evacuation in National Building Code, 2005.
(11) Sewage treatment plant, water
treatment plant, garbage collection centre Electric sub-station, service ducts.
(12) Covered walkways and pathways.
(13) Any other utilities and
facilities as decided by Chief Executive Officer depending upon its
requirement.
(5) Distance between two adjacent
building blocks
Distance between two adjacent building blocks shall
be minimum 6 mtrs. to 16 mtrs, depending on the height of blocks. For building
height up to 18 mtrs., the spacing shall be 6 mtrs. and thereafter the spacing
shall be increased by 1 metre for every addition of 3 mtrs. in height of
building subject to a maximum spacing of 16 mtrs. as per NATIONAL BUILDING
CODE, 2005. If the blocks have dead-end sides facing each other, than the spacing
shall be maximum 9 mtrs. instead of 16 mtrs. Moreover, the allottee may provide
or propose more than 16 mtrs space between two blocks.
(6) The Authority shall have a right
to impose such restriction and limitations as to the number of storey and
extent of height of the building as he considers fit where protected areas,
ancient or historical monuments lie within a radius of one and half kilo metre
from the boundary line of such buildings by recording reasons.
(7) The internal height of the
basement (floor to ceiling) shall be minimum 2.4 mtrs from bottom of beam and
maximum 4.5 metre. Except wherever height of equipments such as electric
generator, air conditioner, fire hydrant etc. is more than 4.5 mete, additional
height equivalent to height of equipments may be permitted. In case of
Automatic/semi automatic/mechanised parking facility also more than 4.5 mtrs,
additional height may be allowed by the Chief Executive Officer depending upon
the technology and requirement of space.
(8) The height of basement shall be
maximum 1.5 metres upto bottom of the slab above the top of the drain. In case
the basement is flush with the ground level adequate light and ventilation
shall be ensured.
(9) Toilet block for visitors,
drivers etc. comprising of minimum a water closet, a bath and 2 urinals shall
be provided on the ground floor.
(10) At least one of the lifts
provided shall be of the specification of goods lift.
(11) Minimum requirement for
sanction/completion: Minimum covered area required for completion shall be as
per lease deed or Memorandum of Understanding or as follows:-
|
S.NO.
|
SIZE OF PLOT(SQ. MTRS.)
|
MINIMUM BUILT UP AREA(AS %OF TOTAL PERMISSIBLE
FAR)
|
|
1.
|
Upto 4000 Sq. Mtrs.
|
50%
|
|
2.
|
Exceeding 4000 Sq. Mtrs. but not exceeding 10000
|
40%
|
|
|
Sq. Mtrs.
|
|
|
3.
|
Exceeding 10000 Sq. Mtrs. but not exceeding 20000
Sq. Mtrs.
|
35%
|
|
4.
|
Exceeding 20000 Sq. Mtrs. but not exceeding
100000 Sq. Mtrs.
|
30%
|
|
5.
|
Exceeding 100000 Sq. Mtrs. but not exceeding
200000 Sq. Mtrs.
|
25%
|
|
6.
|
Exceeding 200000 Sq. Mtrs. but not exceeding
400000 Sq. Mtrs.
|
20%
|
|
7.
|
Above 400000 Sq. Mtrs.
|
15%
|
Note:
(i) No further time extension shall
be required if the completion has been taken by the allottee as per table
mentioned above. The above mentioned completion requirement shall be applicable
in all allotments. In the old allotments, the provisions of project report or
lease deed or previous options may be followed.
(ii) However validity of plans may be
granted to the allottee in multiples of 5 years after taking completion of
minimum area,
(iii) In all the projects of 40
hactares and above, block wise temporary Occupancy may be allowed subject to a
minimum of 1,00,000 sqm built up area, the building completed with all
mandatory provisions of services and the allottee shall segregate these blocks
for the purpose of security during construction period.
(12) Provision of following item in
building shall be mandatory for issue of completion certificate:
(i) Flooring;/i.e. hard surface and
completely finished floors for common areas or/and public use areas.
(ii) Electrical wiring;
(iii) Plumbing work to be complete.
(iv) Parking and landscaping as per
Table no. 5 and Table no. 6 respectively or as per directions issued from time
to time whichever is higher;
(v) Number plate and illumination
board as per direction amended or direction issued from time-to-time;
(vi) Internal and external finishing
(Plastering may not be mandatory);
(vii) Boundary wall and gates shall be
mandatory;
(viii) Buildings shall be lockable i.e.
all external doors and windows shall be provided. In case grill is provided in
the windows the fixing of glass in the windows pane shall not be mandatory;
(ix) No violation should be there in
the overall building or site at the time of issue of occupancy certificate;
(x) Any other special provision as
mentioned in the lease deed;
(xi) In case of completion of whole
project, all temporary structures to be removed. In case if any special clause
is mentioned in the lease deed or Memorandum of Understanding then the
requirement mentioned in the same shall be applicable.
24.5 INSTITUTIONAL
|
Sl. No.
|
Use
|
Maximum ground coverage
|
Maximum FAR
|
Maximum height in metres
|
|
1
|
All Higher Educational Institutions, e.g.
Engineering, Management, Degree college, Research and Training Centre,
Film/Audio/Video Studio, University, vocational institute, etc.
|
35%
|
1.50
|
No limit
|
|
2
|
Higher Secondary School
|
40%
|
1.50
|
24.0
|
|
3
|
Nursery School/Creche/Primary School
|
40%
|
1.50
|
15.0
|
|
4.
|
Religious Building
|
35%
|
1.20
|
No limit
|
|
5.
|
Dispensary/Health care & Social Assistance
services, & Clinic, Clinical lab
|
30%
|
1.50
|
20.0
|
|
6.
|
Hospital in any system of medicine, Naturopathy
centre, Nursing Home Specialized Health Centre, Trauma Centre.
|
30%
|
2.75
|
No limit
|
|
7.
|
Government, Semi-Government, Corporate Offices
& other offices.
|
30%
|
2.00
|
No limit
|
|
8.
|
Museum, Art Gallery and Exhibition Centre, Art
Centre.
|
30%
|
1.50
|
No limit
|
|
9.
|
Information Technology and Information Technology
Enabled Services, Biotech Park
|
30%
|
2.00
|
No limit
|
|
10.
|
Community Centre, Club Building and Barat
Ghar/Gym, Spa/Health Club, Fire Station, Police Station, Post Office, Library
& other such facilities.
|
30%
|
1.50
|
24.0
|
|
11.
|
Dharamshala/Lodge/Guest House/Hostel
|
30%
|
2.50
|
No Limit
|
|
12.
|
Dharam Kanta, Petrol Pump & Gas godown
|
30%
|
0.50
|
15.0
|
|
13.
|
Old age home, orphanage, reformatory
|
30%
|
1.50
|
15.0
|
|
14.
|
Convention/Conference/Socio Cultural/Social
Welfare Centre
|
30%
|
1.50
|
No Limit
|
|
15.
|
Other Utilities
|
30%
|
1.00
|
15.0
|
24.5.1 Other Provisions:
(1) No construction of any kind shall
be permitted beyond the building envelope (on setbacks) except
(i) A Chajja (projection) of maximum
width of 0.75 metre at lintel or roof level. No construction of any type or any
material shall be permitted over projections other than mentioned herewith.
(ii) Underground water tanks with top
flush with the adjoining ground level.
(iii) Watchman Shelters and Watch
Towers with following provisions:
(iv) No projection of watchman
shelters and watch towers shall be allowed outside the plot line.
(v) Maximum height of watchman
shelter shall be 4 metres and for watch towers 15 metres. Total area, as mentioned
below, under such shelters shall be split up in desired number of watch man
shelter and watch towers as follows:
|
Sr. No.
|
Plot Size
|
Total area for watchman shelter and watch tower
|
Maximum area under each watchman shelter
|
Maximum area under each watch tower
|
|
1
|
Upto 0.5 acres
|
15 square metre
|
15 square metre
|
5 square metre
|
|
2
|
Above 0.5 acres upto 10 acres
|
30 square metre
|
24 square metre
|
5 square metre
|
|
3
|
Above 10 acres upto 25 acres
|
45 square metre
|
24 square metre
|
5 square metre
|
|
4
|
Above 25 acres upto 50 acres
|
60 square metre
|
24 square metre
|
5 square metre
|
|
5
|
Above 50 acres for an additional 50 acres
|
An additional 10 square metre and part thereof
|
24 square metre
|
5 square metre
|
(vi) The following features shall be
permitted after leaving minimum 6 mtrs. open corridor for fire tenders.
(a) Metre room as per norms of
Electricity Authority..
(b) Open transformers without any
permanent enclosure keeping in view the necessary safety requirements.
(c) Other features as mentioned in
Table 3
(d) Rockery, well and well structures,
water pool, swimming pool (if uncovered), uncovered platform around tree, tank,
fountain, bench, chabutra with open top and unenclosed by side walls, compound
wall, gate, slide swing, culverts on drains.
(e) Any other feature, primarily
ornamental in nature, not enclosing or covering space of commercial use may be
permitted by the Chief Executive Officer on case to case basis.
(f) Open generator set, filtration
plant, Electrical distribution equipments, feeder pillars, telephone
distribution equipments may be permitted in open setback as a service utility
provided after leaving clear space for fire tender.
(2) Floor Area Ratio shall include
(i) Mezzanine
(ii) The shafts provided for lifts
shall be taken for covered area calculations only on one floor and included in
ground coverage.
(iii) Pergola, shall be counted towards
Floor Area Ratio if closed from three or more than three sides.
(iv) Metre room as per Electricity
Authority norms.
(3) Floor Area Ratio shall not
include:
(i) A cantilever projection at any
level (in setbacks) of a width of 0.75 metre. No construction of any type or
any material shall be permitted over projections.
(ii) Basement(s), shall be permissible
within the setback line on each floor. However maximum permissible area under
basement shall be limited up to:
(a) Basement area, if used for
services, storage etc. then maximum area under such facilities shall be
equivalent to maximum permissible ground coverage.
(b) Basement area/Podium parking as
defined in parking table, if used for parking, then area equivalent to parking
requirement shall be permitted.
(c) In plots bigger than 10000 sq
mtrs. The basement shall be allowed in setback area after leaving a minimum
setback of 6.0 mtrs.
(iii) Basement, if put to any use other
than mentioned above, shall be included in the FAR of the building.
(iv) Stilt area of non-habitable
height 2.40 metres from bottom of beam proposed to be used for parking,
landscaping etc.
(v) Balconies (upto 1.5 metre width)
free from FAR may be projected in open setbacks provided 6 mtrs. clear space is
available for fire tender movement.
(vi) Other features as mentioned in
Table 3.
(vii) Rockery, well and well
structures, water pool, swimming pool (if uncovered), uncovered platform around
tree, tank, fountain, bench, chabutra with open top and unenclosed by side
walls, compound wall, gate, slide, swing, uncovered staircase (unenclosed and
uncovered on three sides except for 0.9 metre high railing/wall and open to
sky), overhead tanks on top of buildings, open shafts, culverts on drains.
(viii) Open ramps with no area enclosed
below it of usable height. If used for approach to the entrance of the
building, then the height as per requirement may be considered. The space under
the ramp shall not be used for any commercial purpose, however it can be
landscaped with approval of the Chief Executive Officer on case to case basis.
(ix) Atrium shall be kept free from
FAR and ground coverage. In case any commercial activity is proposed in Atrium
or any saleable area or any other structure which is counted in FAR &
ground coverage, its respective area shall be added in total FAR & ground
coverage.
(x) Any other feature purely
ornamental in nature and not enclosing or covering space of commercial use may
be permitted by the Chief Executive Officer on case to case basis.
(xi) Additional 5% of the plot area as
ground coverage will be allowed for dedicated multi level parking/podium
parking in plots bigger than 10000 sq mtrs (excluding green areas).
(xii) In multistorey buildings service
floor may be allowed after 4 floors. Maximum of 3 service floors may be allowed
in a building. Service floor shall not be counted in FAR and maximum height of
service floor shall be 2.40 mtrs. from floor to bottom of the beam.
(4) 15% of prescribed FAR shall be
added towards common areas, which shall include the following built structures.
The structures on ground will be counted in Ground Coverage
(1) Canopy projections of area as
mentioned in table 4, no construction of any type shall be permitted over the
canopy. Canopy, if cantilevered and no structure on it having a size of 2.4m x
4.5m shall not be counted in Ground Coverage.
(2) Loft up to maximum height of 1.5
metre.
(3) Air-conditioning plant,
electrical installation, generator room, water works, water tank etc.
(4) Watchmen/Security shelters and
watch towers
(5) Garbage shafts, lift shafts and
10 sq mtr lobby infront of each lift (excluding area of corridor beyond the
lift).
(6) Fire escape staircases
(7) Toilet blocks for visitors,
drivers, guards etc on ground floor only.
(8) Mumty, machine room for lifts.
(9) Cupboards upto a depth of 0.60
mtrs. and 1.80 mtrs. in length.
(10) Bay window upto a depth of 0.60
mtrs. and 2.0 m length.
(11) Refuge area as per definition for
fire evacuation and National Building Code, 2005.
(12) Sewage treatment plant, water treatment
plant, garbage collection centre, Electric sub-station, service ducts.
(13) Covered walkways and pathways.
(14) Any other utilities and
facilities as decided by Chief Executive Officer depending on its requirement.
(5) Distance between two adjacent
building blocks
Distance between two adjacent building blocks shall
be minimum 6 mtrs. to 16 mtrs, depending on the height of blocks. For building
height up to 18 mtrs., the spacing shall be 6 mtrs. and thereafter the spacing
shall be increased by 1 metre for every addition of 3 mtrs. in height of
building subject to a maximum spacing of 16 mtrs. as per NATIONAL BUILDING
CODE, 2005. If the blocks have dead-end sides facing each other, than the
spacing shall be maximum 9 mtrs. instead of 16 mtrs. Moreover, the allottee may
provide or propose more than 16 mtrs space between two blocks.
(6) The Authority shall have a right
to impose such restriction and limitations as to the number of storey and
extent of height of the building as he considers fit where protected areas, ancient
or historical monuments lie within a radius of one and half kilo metre from the
boundary line of such buildings by recording the reasons.
(7) The internal height of the
basement (floor to ceiling) shall be minimum 2.4 mtrs from bottom of beam and
maximum 4.5 metre. Except wherever height of equipments such as electric
generator, air conditioner, fire hydrant etc. is more than 4.5 metre additional
height equivalent to height of equipments may be permitted. In case of Automatic/semi
automatic/mechanised parking facility also more than 4.5 mtrs, additional
height may be allowed by the Chief Executive Officer depending upon the
technology and requirement of space.
(8) The height of basement shall be
maximum 1.5 metres upto bottom of the slab above the top of the drain. In case
the basement is flush with the ground level adequate light and ventilation
shall be ensured.
(9) Toilet block for visitors,
drivers etc. comprising of minimum a water closet, a bath and 2 urinals shall
be provided on the ground floor.
(10) At least one of the lifts
provided shall be of the specification of goods lift.
(11) Minimum requirement for
sanction/completion: Minimum covered area required for completion shall be as
per lease deed or Memorandum of Understanding or as follows:-
|
S. NO.
|
SIZE OF PLOT(SQ. MTRS.)
|
MINIMUM BUILT UP AREA(AS %OF TOTAL PERMISSIBLE
FAR)
|
|
1.
|
Up to 4000 Sq. Mtrs.
|
50%
|
|
2.
|
Exceeding 4000 Sq. Mtrs. but not exceeding 10000
Sq. Mtrs.
|
40%
|
|
3.
|
Exceeding 10000 Sq. Mtrs. but not exceeding 20000
Sq. Mtrs.
|
35%
|
|
4.
|
Exceeding 20000 Sq. Mtrs. but not exceeding
100000 Sq. Mtrs.
|
30%
|
|
5.
|
Exceeding 100000 Sq. Mtrs. but not exceeding
200000 Sq. Mtrs.
|
25%
|
|
6.
|
Exceeding 200000 Sq. Mtrs. but not exceeding
400000 Sq. Mtrs.
|
20%
|
|
7.
|
Above 400000 Sq. Mtrs.
|
15%
|
Note:
(i) No further time extension shall
be required if the completion has been taken by the allottee as per table
mentioned above. The above mentioned completion requirement shall be applicable
in all allotments. In the old allotments, the provisions of project report or
lease deed or previous options may be followed.
(ii) However validity of plans may be
granted to the allottee in multiples of 5 years after taking completion of
minimum area,
(iii) In all the projects of 40
hactares and above, block wise temporary Occupancy may be allowed subject to a
minimum of 1,00,000 sqm built up area, the building completed with all
mandatory provisions of services and the allottee shall segregate these blocks
for the purpose of security during construction period.
(12) Provision of following item in
building shall be mandatory for issue of completion certificate:
(i) Flooring;/i.e. hard surface and
completely finished floors for common areas or/and public use areas.
(ii) Electrical wiring;
(iii) Plumbing work to be complete.
(iv) Parking and landscaping as per
Table no. 5 and Table no. 6 respectively or as per directions issued from time
to time whichever is higher;
(v) Number plate and illumination
board as per direction amended or direction issued from time-to-time;
(vi) Internal and external finishing
(Plastering may not be mandatory);
(vii) Boundary wall and gates shall be
mandatory;
(viii) Buildings shall be lockable i.e.
all external doors and windows shall be provided. In case grill is provided in
the windows the fixing of glass in the windows pane shall not be mandatory;
(ix) No violation should be there in
the overall building or site at the time of issue of occupancy certificate;
(x) Any other special provision as
mentioned in the lease deed;
(xi) In case of completion of whole
project, all temporary structures to be removed. In case if any special clause
is mentioned in the lease deed or Memorandum of Understanding then the
requirement mentioned in the same shall be applicable.
24.6 GREEN AREAS
|
Sl. No.
|
Use
|
Maximum ground coverage
|
Maximum FAR
|
Maximum height in metres
|
|
1
|
Sports and Amusement Complex, Stadia, Swimming
Pool, Shooting Range, Recreational Green/Park complex with sports facilities
|
20%
|
0.40 + 0.20 purchasable
|
24.0
|
|
2
|
Low Density Sports & Amusement Complex,
Recreational Club, Social Cultural Centre
|
10%
|
0.20 + 0.10 purchasable
|
24.0
|
|
3
|
Institutional Green
|
35%
|
0.80+0.20 Purchasable
|
only for
Institutional
activity
|
|
4
|
Nursery
|
50 sqmtrs
|
50 sqmts.
|
6.0
|
24.6.1 Other Provisions:
(1) No construction of any kind shall
be permitted beyond the building envelope (on setbacks) except
(i) A Chajja (projection) of maximum
width of 0.75 metre at lintel or roof level. No construction of any type or any
material shall be permitted over projections other than mentioned herewith.
(ii) Underground water tanks with top
flush with the adjoining ground level.
(iii) Watchman Shelters and Watch
Towers with following provisions:
(iv) No projection of watchman
shelters and watch towers shall be allowed outside the plot line.
(v) Maximum height of watchman
shelter shall be 4 metres and for watch towers 15 metres. Total area, as
mentioned below, under such shelters shall be split up in desired number of
watch man shelter and watch towers as follows:
|
Sr. No.
|
Plot Size
|
Total area for watchman shelter and watch tower
|
Maximum area under each watchman shelter
|
Maximum area under each watch tower
|
|
1
|
Upto 0.5 acres
|
15 square metres
|
15 square metres
|
5 square metres
|
|
2
|
Above 0.5 acres upto 10 acres
|
30 square metres
|
24 square metres
|
5 square metres
|
|
3
|
Above 10 acres upto 25 acres
|
45 square metres
|
24 square metres
|
5 square metres
|
|
4
|
Above 25 acres upto 50 acres
|
60 square metres
|
24 square metres
|
5 square metres
|
|
5
|
Above 50 acres for an additional 50 acres
|
An additional 10 square metre and part thereof
|
24 square metres
|
5 square metres
|
(vi) The following features shall be
permitted after leaving minimum 6 mtrs. open corridor for fire tenders.
(a) Metre room as per norms of
Electricity Authority..
(b) Open transformers without any
permanent enclosure keeping in view the necessary safety requirements.
(c) Other features as mentioned in
Table 3
(d) Rockery, well and well
structures, water pool, swimming pool (if uncovered), uncovered platform around
tree, tank, fountain, bench, chabutra with open top and unenclosed by side
walls, compound wall, gate, slide swing, culverts on drains.
(e) Any other feature, primarily
ornamental in nature, not enclosing or covering space of commercial use may be
permitted by the Chief Executive Officer on case to case basis.
(f) Open generator set, filtration
plant, Electrical distribution equipments, feeder pillars, telephone
distribution equipments may be permitted in open setback as a service utility
provided after leaving clear space for fire tender.
(2) Floor Area Ratio shall include
(i) Mezzanine
(ii) The shafts provided for lifts
shall be taken for covered area calculations only on one floor and included in
ground coverage.
(iii) Pergola, shall be counted towards
Floor Area Ratio if closed from three or more than three sides.
(iv) Metre room as per Electricity
Authority norms.
(3) Floor Area Ratio shall not
include:
(i) A cantilever projection at any
level (in setbacks) of a width of 0.75 metre. No construction of any type or
any material shall be permitted over projections.
(ii) Basement area equivalent to
maximum permissible ground coverage for services, storage and parking.
(iii) Basement, if put to any use other
than mentioned above, shall be included in the FAR of the building.
(iv) Stilt area of non-habitable
height 2.40 metres from bottom of beam proposed to be used for parking,
landscaping etc.
(v) Balconies (up to 1.5 metre width)
free from FAR may be projected in open setbacks provided 6 mtrs. clear space is
available for fire tender movement.
(vi) Other features as mentioned in
Table 3.
(vii) Rockery, well and well
structures, water pool, swimming pool (if uncovered), uncovered platform around
tree, tank, fountain, bench, chabutra with open top and unenclosed by side
walls, compound wall, gate, slide, swing, uncovered staircase (unenclosed and
uncovered on three sides except for 0.9 metre high railing/wall and open to sky),
overhead tanks on top of buildings, open shafts, culverts on drains.
(viii) Open ramps with no area enclosed
below it of usable height. If used for approach to the entrance of the
building, then the height as per requirement may be considered. The space under
the ramp shall not be used for any commercial purpose, however it can be
landscaped with approval of the Chief Executive Officer on case to case basis.
(ix) Any other feature purely
ornamental in nature and not enclosing or covering space of commercial use may
be permitted by the Chief Executive Officer on case to case basis.
(4) 15% of prescribed FAR shall be
added towards common areas, which shall include the following built structures.
The structures on ground will be counted in Ground Coverage
(1) Canopy projections of area as
mentioned in table 4, no construction of any type shall be permitted over the
canopy. Canopy, if cantilevered and no structure on it having a size of 2.4m x
4.5m shall not be counted in Ground Coverage.
(2) Loft up to maximum height of 1.5
metre.
(3) Air-conditioning plant,
electrical installation, generator room, water works, water tank etc.
(4) Watchmen/Security shelters and
watch towers
(5) Garbage shafts, lift shafts and
10 sq mtr lobby infront of each lift (excluding area of corridor beyond the
lift).
(6) Fire escape staircases
(7) Toilet blocks for visitors,
drivers, guards etc on ground floor only.
(8) Mumty, machine room for lifts.
(9) Cupboards up to a depth of 0.60
mtr and 1.80 mtrs. in length.
(10) Bay window up to a depth of 0.60
mtr and 2.0 m length.
(11) Refuge area as per definition for
fire evacuation in National Building Code, 2005.
(12) Sewage treatment plant, water
treatment plant, garbage collection centre Electric sub-station, service ducts.
(13) Covered walkways and pathways.
(14) Any other utilities and facilities
as decided by Chief Executive Officer depending upon its requirement.
(5) Distance between two adjacent
building blocks Distance between two adjacent building blocks shall be minimum
6 mtrs. to 16 mtrs, depending on the height of blocks. For building height up
to 18 mtrs., the spacing shall be 6 mtrs. and thereafter the spacing shall be
increased by 1 metre for every addition of 3 mtrs. in height of building
subject to a maximum spacing of 16 mtrs. as per NATIONAL BUILDING CODE, 2005.
If the blocks have dead-end sides facing each other, than the spacing shall be
maximum 9 mtrs. instead of 16 mtrs. Moreover, the allottee may provide or
propose more than 16 mtrs space between two blocks.
(6) The Authority shall have a right
to impose such restriction and limitations as to the number of storey and
extent of height of the building as he considers fit where protected areas,
ancient or historical monuments lie within a radius of one and half kilo metre
from the boundary line of such buildings by recording the reasons.
(7) The internal height of the
basement (floor to ceiling) shall be minimum 2.4 mtrs from bottom of beam and
maximum 4.5 metre. Except wherever height of equipments such as electric
generator, air conditioner, fire hydrant etc. is more than 4.5 metre,
additional height equivalent to height of equipments may be permitted. In case
of Automatic/semi automatic/mechanised parking facility also more than 4.5
mtrs, additional height may be allowed by the Chief Executive Officer depending
upon the technology and requirement of space.
(8) The height of basement shall be
maximum 1.5 metres upto bottom of the slab above the top of the drain. In case
the basement is flush with the ground level adequate light and ventilation
shall be ensured.
(9) Toilet block for visitors,
drivers etc. comprising of minimum a water closet, a bath and 2 urinals shall
be provided on the ground floor.
(10) At least one of the lifts
provided shall be of the specification of goods lift.
(11) Minimum requirement for
sanction/completion: Minimum covered area required for completion shall be as
per lease deed or Memorandum of Understanding or as follows:-
|
S.NO.
|
SIZE OF PLOT(SQ. MTRS.)
|
MINIMUM BUILT UP AREA(AS %OF TOTAL PERMISSIBLE
FAR)
|
|
1.
|
Up to 4000 Sq. Mtrs.
|
50%
|
|
2.
|
Exceeding 4000 Sq. Mtrs. but not exceeding 10000
Sq. Mtrs.
|
40%
|
|
3.
|
Exceeding 10000 Sq. Mtrs. but not exceeding 20000
Sq. Mtrs.
|
35%
|
|
4.
|
Exceeding 20000 Sq. Mtrs. but not exceeding
100000 Sq. Mtrs.
|
30%
|
|
5.
|
Exceeding 100000 Sq. Mtrs. but not exceeding
200000 Sq. Mtrs.
|
25%
|
|
6.
|
Exceeding 200000 Sq. Mtrs. but not exceeding
400000 Sq. Mtrs.
|
20%
|
|
7.
|
Above 400000 Sq. Mtrs.
|
15%
|
Note:
(i) No further time extension shall
be required if the completion has been taken by the allottee as per table
mentioned above. The above mentioned completion requirement shall be applicable
in all allotments. In the old allotments, the provisions of project report or
lease deed or previous options may be followed.
(ii) However validity of plans may be
granted to the allottee in multiples of 5 years after taking completion of
minimum area,
(iii) In all the projects of 40
hactares and above, block wise temporary Occupancy may be allowed subject to a
minimum of 1,00,000 sqm built up area, the building completed with all
mandatory provisions of services and the allottee shall segregate these blocks
for the purpose of security during construction period.
(12) Provision of following item in
building shall be mandatory for issue of completion certificate:
(i) Flooring;/i.e. hard surface and
completely finished floors for common areas or/and public use areas.
(ii) Electrical wiring;
(iii) Plumbing work to be complete.
(iv) Parking and landscaping as per
Table no. 5 and Table no. 6 respectively or as per directions issued from time
to time whichever is higher;
(v) Number plate and illumination
board as per direction amended or direction issued from time-to-time;
(vi) Internal and external finishing
(Plastering may not be mandatory);
(vii) Boundary wall and gates shall be
mandatory;
(viii) Buildings shall be lockable i.e.
all external doors and windows shall be provided. In case grill is provided in
the windows the fixing of glass in the windows pane shall not be mandatory;
(ix) No violation should be there in
the overall building or site at the time of issue of occupancy certificate;
(x) Any other special provision as
mentioned in the lease deed;
(xi) In case of completion of whole
project, all temporary structures to be removed. In case if any special clause
is mentioned in the lease deed or Memorandum of Understanding then the
requirement mentioned in the same shall be applicable
24.7 TRANSPORTATION
|
Sl. No.
|
Use
|
Maximum ground coverage
|
Maximum FAR
|
Maximum height in metres
|
|
1
|
Bus Terminal, ISBT, Light Rail Transit Terminal,
Bus Depots/workshop, Booking Offices, Transport Nagar
|
30%
|
2.00
|
No limit
|
|
2
|
Any other item not covered in this table
|
To be decided by the Authority
|
To be decided by the Authority
|
To be decided by the Authority
|
24.7.1 Other Provisions:
(1) No construction of any kind shall
be permitted beyond the building envelope (on setbacks) except
(i) A Chajja (projection) of maximum
width of 0.75 metre at lintel or roof level. No construction of any type or any
material shall be permitted over projections other than mentioned herewith.
(ii) Underground water tanks with top
flush with the adjoining ground level.
(iii) Watchman Shelters and Watch
Towers with following provisions:
(iv) No projection of watchman
shelters and watch towers shall be allowed outside the plot line.
(v) Maximum height of watchman
shelter shall be 4 metres and for watch towers 15 metres. Total area, as mentioned
below, under such shelters shall be split up in desired number of watch man
shelter and watch towers as follows:
|
Sr. No.
|
Plot Size
|
Total area for watchman shelter and watch tower
|
Maximum area under each watchman shelter
|
Maximum area under each watch tower
|
|
1
|
Up to 0.5 acres
|
15 square metres
|
15 square metres
|
5 square metres
|
|
2
|
Above 0.5 acres up to 10 acres
|
30 square metres
|
24 square metres
|
5 square metres
|
|
3
|
Above 10 acres up to 25 acres
|
45 square metres
|
24 square metres
|
5 square metres
|
|
4
|
Above 25 acres up to 50 acres
|
60 square metres
|
24 square metres
|
5 square metres
|
|
5
|
Above 50 acres for an additional 50 acres
|
An additional 10 square metres and part thereof
|
24 square metres
|
5 square metres
|
(vi) The following features shall be
permitted after leaving minimum 6 mtrs. open corridor for fire tenders.
(a) Metre room as per norms of
Electricity Authority..
(b) Open transformers without any
permanent enclosure keeping in view the necessary safety requirements.
(c) Other features as mentioned in
Table 3
(d) Rockery, well and well
structures, water pool, swimming pool (if uncovered), uncovered platform around
tree, tank, fountain, bench, chabutra with open top and unenclosed by side
walls, compound wall, gate, slide swing, culverts on drains.
(e) Any other feature, primarily
ornamental in nature, not enclosing or covering space of commercial use may be
permitted by the Chief Executive Officer on case to case basis.
(f) Open generator set, filtration
plant, Electrical distribution equipments, feeder pillars, telephone
distribution equipments may be permitted in open setback as a service utility
provided after leaving clear space for fire tender.
(2) Floor Area Ratio shall include
(i) Mezzanine
(ii) The shafts provided for lifts
shall be taken for covered area calculations only on one floor and included in
ground coverage.
(iii) Pergola, shall be counted towards
Floor Area Ratio if closed from three or more than three sides.
(iv) Metre room as per Electricity
Authority norms.
(3) Floor Area Ratio shall not
include:
(i) A cantilever projection at any
level (in setbacks) of a width of 0.75 metre. No construction of any type or
any material shall be permitted over projections.
(ii) Basement(s) shall be permissible
within the setback line on each floor. However maximum permissible area under
basement shall be limited up to:
(a) Basement area, if used for
services, storage etc. then maximum area under such facilities shall be
equivalent to maximum permissible ground coverage.
(b) Basement area/Podium parking as
defined in parking table, if used for parking, then area equivalent to parking
requirement shall be permitted.
(c) In plots bigger than 10000 sq
mtrs. The basement shall be allowed in setback area after leaving a minimum
setback of 6.0 mtrs.
(iii) Basement, if put to any use other
than mentioned above, shall be included in the FAR of the building.
(iv) Stilt area of non-habitable
height 2.40 metres from bottom of beam proposed to be used for parking,
landscaping etc.
(v) Balconies (upto 1.5 metre width)
free from FAR may be projected in open setbacks provided 6 mtrs. clear space is
available for fire tender movement.
(vi) Other features as mentioned in
Table 3.
(vii) Rockery, well and well
structures, water pool, swimming pool (if uncovered), uncovered platform around
tree, tank, fountain, bench, chabutra with open top and unenclosed by side
walls, compound wall, gate, slide, swing, uncovered staircase (unenclosed and
uncovered on three sides except for 0.9 metre high railing/wall and open to
sky), overhead tanks on top of buildings, open shafts, culverts on drains.
(viii) Open ramps with no area enclosed
below it of usable height. If used for approach to the entrance of the
building, then the height as per requirement may be considered. The space under
the ramp shall not be used for any commercial purpose, however it can be
landscaped with approval of the Chief Executive Officer on case to case basis.
(ix) Atrium shall be kept free from
FAR and ground coverage. In case any commercial activity is proposed in Atrium
or any saleable area or any other structure which is counted in FAR &
ground coverage, its respective area shall be added in total FAR & ground
coverage.
(x) Any other feature purely
ornamental in nature and not enclosing or covering space of commercial use may
be permitted by the Chief Executive Officer on case to case basis.
(xi) Additional 5% of the plot area as
ground coverage will be allowed for dedicated multi level parking in plots
bigger than 10000 sq mtrs (excluding green areas).
(xii) In multistorey buildings service
floor may be allowed after 4 floors. Maximum of 3 service floors may be allowed
in a building. Service floor shall not be counted in FAR and maximum height of
service floor shall be 2.40 mtrs. from floor to bottom of the beam.
(4) 15% of prescribed FAR shall be
added towards common areas, which shall include the following built structures.
The structures on ground will be counted in Ground Coverage
(1) Canopy projections of area as
mentioned in table 4, no construction of any type shall be permitted over the
canopy. Canopy, if cantilevered and no structure on it having a size of 2.4m x
4.5m shall not be counted in Ground Coverage.
(2) Loft up to maximum height of 1.5
metre.
(3) Air-conditioning plant,
electrical installation, generator room, water works, water tank etc.
(4) Watchmen/Security shelters and
watch towers
(5) Garbage shafts, lift shafts and
10 sq mtr lobby infront of each lift (excluding area of corridor beyond the
lift).
(6) Fire escape staircases
(7) Toilet blocks for visitors,
drivers, guards etc on ground floor only.
(8) Mumty, machine room for lifts.
(9) Cupboards up to a depth of 0.60
mtr and 1.80 mtrs. in length.
(10) Refuge area as per definition for
fire evacuation in National Building Code, 2005.
(11) Sewage treatment plant, water
treatment plant, garbage collection centre, Electric sub-station, service
ducts.
(12) Covered walkways and pathways.
(13) Any other utilities and facilities
as decided by Chief Executive Officer depending upon its requirement.
(5) Distance between two adjacent
building blocks Distance between two adjacent building blocks shall be minimum
6 mtrs. to 16 mtrs, depending on the height of blocks. For building height up
to 18 mtrs., the spacing shall be 6 mtrs. and thereafter the spacing shall be
increased by 1 metre for every addition of 3 mtrs. in height of building
subject to a maximum spacing of 16 mtrs. as per NATIONAL BUILDING CODE, 2005.
If the blocks have dead-end sides facing each other, than the spacing shall be
maximum 9 mtrs. instead of 16 mtrs. Moreover, the allottee may provide or
propose more than 16 mtrs space between two blocks.
(6) The Authority shall have a right
to impose such restriction and limitations as to the number of storey and
extent of height of the building as he considers fit where protected areas,
ancient or historical monuments lie within a radius of one and half kilo metre
from the boundary line of such buildings by recording the reasons.
(7) The internal height of the
basement (floor to ceiling) shall be minimum 2.4 mtrs from bottom of beam and
maximum 4.5 metre. Except wherever height of equipments such as electric
generator, air conditioner, fire hydrant etc. is more than 4.5 metre,
additional height equivalent to height of equipments may be permitted. In case
of Automatic/semi automatic/mechanised parking facility also more than 4.5
mtrs, additional height may be allowed by the Chief Executive Officer depending
upon the technology and requirement of space.
(8) The height of basement shall be
maximum 1.5 metres upto bottom of the slab above the top of the drain. In case
the basement is flush with the ground level adequate light and ventilation
shall be ensured.
(9) Toilet block for visitors,
drivers etc. comprising of minimum a water closet, a bath and 2 urinals shall
be provided on the ground floor.
(10) At least one of the lifts
provided shall be of the specification of goods lift.
(11) Minimum requirement for
sanction/completion: Minimum covered area required for completion shall be as
per lease deed or Memorandum of Understanding or as follows:-
|
S.NO.
|
SIZE OF PLOT(SQ. MTRS.)
|
MINIMUM BUILT UP AREA(AS %OF TOTAL PERMISSIBLE
FAR)
|
|
1.
|
Upto 4000 Sq. Mtrs.
|
50%
|
|
2.
|
Exceeding 4000 Sq. Mtrs. but not exceeding 10000
Sq. Mtrs.
|
40%
|
|
3.
|
Exceeding 10000 Sq. Mtrs. but not exceeding 20000
Sq. Mtrs.
|
35%
|
|
4.
|
Exceeding 20000 Sq. Mtrs. but not exceeding
100000 Sq. Mtrs.
|
30%
|
|
5.
|
Exceeding 100000 Sq. Mtrs. but not exceeding
200000 Sq. Mtrs.
|
25%
|
|
6.
|
Exceeding 200000 Sq. Mtrs. but not exceeding
400000 Sq. Mtrs.
|
20%
|
|
7.
|
Above 400000 Sq. Mtrs.
|
15%
|
Note:
(i) No further time extension shall
be required if the completion has been taken by the allottee as per table
mentioned above. The above mentioned completion requirement shall be applicable
in all allotments. In the old allotments, the provisions of project report or
lease deed or previous options may be followed.
(ii) However validity of plans may be
granted to the allottee in multiples of 5 years after taking completion of
minimum area,
(iii) In all the projects of 40
hactares and above, block wise temprorary Occupancy may be allowed subject to a
minimum of 1,00,000 sqm built up area, the building completed with all
mandatory provisions of services and the allottee shall segregate these blocks
for the purpose of security during construction period.
(12) Provision of following item in
building shall be mandatory for issue of completion certificate:
(i) Flooring;/i.e. hard surface and
completely finished floors for common areas or/and public use areas.
(ii) Electrical wiring;
(iii) Plumbing work to be complete.
(iv) Parking and landscaping as per
Table no. 5 and Table no. 6 respectively or as per directions issued from time
to time whichever is higher;
(v) Number plate and illumination
board as per direction amended or direction issued from time-to-time;
(vi) Internal and external finishing
(Plastering may not be mandatory);
(vii) Boundary wall and gates shall be
mandatory;
(viii) Buildings shall be lockable i.e.
all external doors and windows shall be provided. In case grill is provided in
the windows the fixing of glass in the windows pane shall not be mandatory;
(ix) No violation should be there in
the overall building or site at the time of issue of occupancy certificate;
(x) Any other special provision as
mentioned in the lease deed;
(xi) In case of completion of whole
project, all temporary structures to be removed. In case if any special clause
is mentioned in the lease deed or Memorandum of Understanding then
the requirement mentioned in the same shall be applicable.
24.8 General Provisions for Building/projects in regulations 24.1, 24.2,
24.3, 24.4, 24.5,24.6, 24.7
(1) (i) Category of buildings
mentioned in the above regulations is indicative only.
(ii) If there is any variation in he zoning
regulations of Development Plan/Master Plan, the provisions of Master Plan
shall prevail. (ii) In case of mixed land use Ground coverage and F.A.R shall
be determined on the basis of prime use/activity as decided in the scheme.
(2) Total height shall be counted
from top of external drain to top of the building except for
Illuminated boards
Water Tanks, mumty and machine room
Other such structures with non usable height.
(3) Minimum permissible setbacks
shall be as per Table no. 1 and 2. If there is no mention in the lease deed
then as per Building Regulations prevailing at the time of allotment.
(4) Maximum permissible density shall
be as per lease deed. Maximum density variation of -50 percent and +5 percent
shall be allowed in Group Housing.
(5) The above regulations are for
general applications.
(6) The Authority shall however
prepare and provide Architectural control drawing/Architectural control for
each commercial project.
(7) Notwithstanding anything
contained in these regulations, the Authority may where it considers expedient
to do so, having regard to the special features of a particular zone/sector and
the width of road abutting and the Development Plan, permit such ground
coverage FAR, height and setback in relation to a building or a group of
buildings by recording the reasons.
(8) Provisions of Ground coverage,
FAR, building height, parking etc., for Information Technology (IT) and
Information Technology and Enabled Services in Industrial plots shall be
applicable as per the provisions for Information Technology and Information
Technology and Enabled Services in Institutional plots. This provision is
applicable for those plots which were originally allotted for IT/ITES.
(9) In case of any activity other
than listed above mentioned regulations (24.1 to 24.7), the ground coverage and
FAR shall be decided by the Authority keeping in view the similar kind of
activities mentioned in these regulations.
(10) For buildings of height above, 30
metres necessary clearance from Airport Authority of India shall be taken.
Total height of the building shall be counted from the top of the external
drain to top of the building without exemption.
(11) The above regulations are for
general applications.
(12) Purchasable FAR shall be
available only for those allottees whose allotment was based on specific FAR.
(13) For Horticulture Nursery, the
following provisions shall be applicable:
(i) Green house up to maximum 10
percent of plot area.
(ii) Watchman shelters as per clause
(v) of sub regulation (I) of regulation 24.6.1 and also permitted in setbacks.
(iii) Metre room as per norms of
Electricity Authority and shall also be permitted in setbacks.
(iv) Shops and support facilities
shall be permitted maximum upto 15 sq mtrs included in permitted Ground
Coverage.
(v) Setback shall be as per Table 2.
(14) The applicant who shall construct
Green Building on a plot of 5000 sq mtrs and above for any use may be allowed
an additional FAR of 5% of the permissible/availed FAR (excluding additional
15% of prescribed FAR for services), free of cost, provided that the applicant
fulfils the following conditions:-
(i) The Building is completed and
rated by Leadership in Energy and Environmental Design Leadership in energy and
Environmental Design as 'Gold or Platinum'.
(ii) The building is recommended by
the Bureau of Energy Efficiency Government of India for the provision of energy
efficiency.
(iii) The Building has been completed
fulfilling the parking and landscaping norms of the prevailing regulations.
(iv) The applicant has made sufficient
provisions for using the additional FAR. Note: The applicant has to submit a
certificate of compliance of green building from Leadership in Energy and
Environmental Design (LEED)/Bureau Energy of Efficiency after every three
years. In case he fails to submit this certificate the Authority, after giving
him one month notice, may charge the compounding fees of the FAR given free of
cost at the rate of 200% of the cost of purchasable FAR.
(15) The Authority is authorized to
permit additional height at focal points wherever it is considered appropriate
by recording the reasons.
(16) Enclosure of balcony in any type
of building shall not be permitted or/and compounded. Enclosure shall be
considered as illegal construction.
24.9 Informal Sector
|
(1)
|
Plotted Development
|
|
I.
|
Plot Size
|
:
|
20-25 square metre
|
|
II.
|
Ground Coverage
|
:
|
80 percent
|
|
III.
|
FAR
|
:
|
2.00
|
|
IV.
|
Height
|
:
|
10 metre maximum
|
|
V.
|
Setback
|
:
|
1.5 metre in front
|
|
VI.
|
Roads
|
:
|
Main vehicular roads shall not be less than 9.0
metres and access to plots shall be provided through roads/passages not less
than 6.0 metres.
|
|
VII.
|
Open space
|
:
|
May be provided in a group or Cluster
|
|
(2)
|
Flatted Development
|
|
I.
|
Ground coverage
|
:
|
40 percent
|
|
II.
|
FAR
|
:
|
2.00
|
|
III.
|
Setback
|
:
|
9.0 front 3.0 metre rear and 3.0 metre side
setback
|
|
IV.
|
Height
|
:
|
No Limit
|
|
V.
|
Balcony
|
:
|
0.9 metre wide.
|
|
VI.
|
Roads
|
:
|
Main vehicular roads 12 metre
|
|
VII.
|
Other spaces
|
:
|
60 percent (Open + Roads + Parks)
|
|
VIII.
|
Individual toilets or group may be provided
|
|
(3)
|
Dormitory
|
|
I.
|
Ground coverage/FAR
|
:
|
40 percent/1.60
|
|
II.
|
Setback
|
:
|
9.0 in front 3.0 metre and 3.0 in side setback
|
|
III.
|
Height
|
:
|
15 metre (Maximum)
|
|
IV.
|
Balcony
|
:
|
0.9 metre wide.
|
Common facilities for development
(i) Toilet blocks.
(ii) Proposed plantation on road side
has to be ever green trees planted 10 metre centre to centre.
(iii) Provisions for community
facilities like Creche, Balwadi, Health care centre etc. to be made as per
population requirement.
(iv) The population size of unit shall
be 2.5 person per unit or as decided by the Authority.
(v) The number of Dwelling Units
permissible will be equivalent to number of members in the registered society
or as decided by the Authority with the maximum variation of ñ10 percent.
24.10 Layout And Sub-Division Of
Land:
(1) All provisions shall be as per
sub-division regulations in master plan approved by the Authority. In case of
any special provision in lease deed, the conditions of lease deed shall
prevail.
(2) Setbacks, FAR, ground coverage
and height permissible on the sub divided plot shall be as per maximum
permissible in each individual use in these Regulations
24.11 Standards for facilities
for group housing projects as per following population norms:
|
S.No.
|
Use premises
|
Service population per unit
|
Minimum area per unit (in ha)
|
|
a)
|
Education
|
|
|
|
1.
|
Nursery school/cr?che
|
10000
|
0.10
|
|
2.
|
Senior Secondary school
|
20000-30000
|
0.80
|
|
3.
|
College
|
80000-100000
|
1.0
|
|
b)
|
Health
|
|
|
|
1.
|
Nursing home/Dispensary
|
15000-20000
|
0.10
|
|
2.
|
Hospital
|
100000
|
2.0
|
|
c)
|
Socio - Cultural
|
|
|
|
1.
|
Community Hall and library
|
25000
|
0.40
|
|
2.
|
Recreational club
|
100000
|
1.00
|
|
d)
|
Shopping
|
|
|
|
1.
|
Convenient shopping/
|
1% of permissible group housing FAR
|
|
|
|
Local/sector shopping
|
|
|
e)
|
Other community facilities
|
|
|
|
1.
|
Milk booths
|
10000-15000
|
0.020
|
|
2.
|
Religious building
|
25000-35000
|
0.100
|
|
f)
|
Recreation/Green Parks
|
|
|
|
. 1
|
Park and Play Ground
|
15% of plot area
|
|
|
|
|
|
|
|
g)
|
Utilities
|
|
|
|
1.
|
Overhead tank
|
As per requirement
|
|
|
2.
|
Electric sub station
|
As per requirement
|
|
|
3.
|
Auto cum taxi stand
|
25000
|
0.050
|
|
4.
|
Police Chowki
|
25000
|
0.050
|
|
5.
|
Petrol pump/Gas station
|
50000-100000
|
0.200
|
Note:
(i) Provision of these facilities is
mandatory in Group Housing/Residential schemes. However, the Authority may
allow more numbers for social/community facilities (Non-commercial) and more
areas as per requirement of any project within the limits of permissible FAR.
(ii) For facilities like Nursery
School/Creche, Nursing Home, Dispensary, convenient shops, etc. instead of
earmarking plots, the permissible FAR may be planned on Ground Floor of Group
housing Blocks or as separate building blocks within the permissible ground
coverage. The allottee shall be free to plan the facilities either in the form
of plots or building blocks.
24.12 Provision of Social and
Physical Infrastructure at Sector Level (Zone R) (If facilities are provided as
per sector norms then in individual group housing pockets the facilities
indicated in regulation 24.11 shall not be applicable)
|
Sl.
No.
|
Use Premises
|
Service Population Per Unit
|
Unit Area in Ha
|
|
a)
|
Education
|
|
|
|
1.
|
Creche and Day Care Centre
|
5000-25,000
|
0.100
|
|
2.
|
Nursery School
|
5,000 - 7,500
|
0.100
|
|
3.
|
Primary School
|
7,500-15,000
|
0.200
|
|
4.
|
Senior Secondary School
|
15,000
25,000
|
0.800
|
|
|
|
b)
|
Health
|
|
|
|
1.
|
Dispensary
|
7,500
15,000
|
0.100
|
|
2.
|
Nursing Home
|
5,000 - 7,500
|
0.100
|
|
|
|
|
|
|
c)
|
Shopping
|
|
|
|
1.
|
Convenient Shopping Centres, sector shopping cum
service centre
|
7,500
15,000
|
0.5000
|
|
2.
|
Kiosks/hawker area
|
|
|
|
|
|
|
|
|
d)
|
Other Community Facilities
|
|
|
|
1.
|
Community Centre
|
7,500
15,000
|
0.4000
|
|
2.
|
Milk and Vegetable Booth
|
5,000 - 7,500
|
0.020
|
|
|
|
|
|
|
e)
|
Recreation
|
|
|
|
1.
|
Park and Playground
|
15% of plot/sector
|
Min area per unit 0.2500
|
|
|
|
f)
|
Utilities
|
|
|
|
1.
|
Electric Sub-Station 11 KV
|
As per requirement
|
0.050
|
|
2.
|
Auto Cum Taxi Stand
|
As per requirement
|
0.050
|
24.13 Note:-
In special circumstances the Authority may, relax
any of the provisions mentioned herewith in the regulation no. 24.12 by
recording the reasons.
24.14 Note:-
Provisions of minimum parking and landscaping
requirement shall be as per Table 5 and Table 6 respectively. However, the
Authority may stipulate higher provisions in future as per requirement and
issue directions in this regard.
24.15 Provisions for special
Development Zone (Including mini and micro Special Development Zone);
Applicable only for Yamuna Expressway Industrial Development Authority
(a) Conceptual plan shall be prepared
for Special Development zone.
(b) Minimum area required for the
approval of detailed layout plan for Special Development zone shall be 40% of
the permissible area earmarked for the core activity.
(c) The completion period for 40% of
permissible area for core activity shall be as per the provisions of
allotment/lease deed.
(d) Maximum 1.75 FAR shall be
permitted on the entire land of Special Development zone.
(e) Maximum 30% ground coverage and
1.75 FAR shall be permitted for the core activities of Special Development
Zone. There shall not be any restriction on height of building, however, no
objection certificate from the Airport Authority of India shall be obtained in
case of building height is 30 mtrs and above.
(f) Activities in special Development
Zones shall be allowed as per the appendix -13.
CHAPTER - IV
Regulation - 25. Structural Safety-Fire Safety and Service.
25.1 Fire Safety Requirements
(a) Building shall be so planned, designed and constructed so as to ensure
fire safety and this shall be done in accordance with Part IV 'Fire Protection'
of the National Building Code of India as amended from time to time.
(b) In case of multi-storeyed buildings above 15 metre in height, building
which are more than three storeys and building with more than 400 square metres
ground floor coverage and all other buildings of industrial, storage, assembly
and hazardous type building scheme, provisions of Uttar Pradesh Agni Nivaran
aur Agni Suraksha Adhinam (Act no. 6 of 2005) shall apply.
25.2 Structural Design
The structural design of any item of masonry,
timber, plain concrete and steel in a building shall be carried out in
accordance with Part VI (Structural Design, Section-1, Boards, Section-2,
Section-5, Contrite, Section-6 Steel, as the case may be) of National Building
Code of India NATIONAL BUILDING CODE, 2005 prepared by Indian Standard
Institution and as prevalent at the time of execution of the works.
25.3 Quality of Material and Workmanship
All materials and workmanship shall be of good
quality conforming generally to accepted standards of Public Work Department of
Uttar Pradesh, Indian Standards Specifications and Codes as included in Part V
Building Materials and Part VII Constructional Practices and Safety of National
Building Code of India 2005 as amended from time to time.
25.4 Building Services
The planning design and installation of electrical
installations, air-conditioning and heating work, installation of lifts and
escalators in a building shall be carried out in accordance with Part VIII (Building
Services, Section 2, Electrical Installations, Section 3, Air-conditioning and
heating, Section-5, Installation of lifts and escalators, as the easy may be)
of National Building Code of India 2005 prepared by Indian Standard Institution
and as prevalent at the time of execution of the work.
25.5 Plumbing
The planning design, construction and installation
of water supply, drainage and sanitation and gas supply system in building
shall be in accordance with the Part IX (Plumbing Services Section I, Water
Supply Section 1, Drainage and Sanitation, Section-1, Gas Supply, section 2) of
National Building Code of India prepared by Indian Standard Institution as
amended from time to time.
25.6 Water supply requirements
The requirements of water supply in a building
shall be in accordance with the provision of National Building Code as amended
from time to time.
25.7 Sanitary Fitting
(1) Subject to the provision of any law for the time being in force, the
sanitary fittings and installations in building shall be in accordance with the
provisions of National Building Code as amended from time to time.
(2) Every factory building within the area shall be provided with such
latrines and urinals as may be prescribed by or under the provisions of the
Factories Act 1948 as amended from time to time.
25.8 Structural Safety for Natural Hazard Protection-
For buildings more than three storeys (including
ground floor) or more than 12.0 metre height and important facilities like
water works, overhead tank, telephone exchange, bridges and culverts, electric
substation, transmission towers, the requirements specified in the Indian
Standard Code and Guidelines and other documents shall be observed for
structural safety and natural hazards protection of buildings. The details of
the relevant codes and guidelines are given in Appendix 8-A/B/C/D.
25.9 Provision for Physically Handicapped
Provisions for physically handicapped persons shall
be made in all buildings and facilities used by public in accordance with the
provision of Part III, Annex D of National Building Code -2005.
25.10 Note:-
All the provisions made in the building which are
not specifically provided in these regulations shall be as per the provisions
of National Building Code, Indian Standard Institution Code as amended from
time to time. The technical person shall be responsible for ensuring the same
as per Appendix-4.
25.11 Note:-
The Owner, Technical Person shall be fully
responsible for all provisions to be made in accordance with clause 25.1, 25.2,
25.3, 25.4, 25.5, 25.6, 25.7, 25.8, 25.9 & 25.10. A certificate to this
effect shall be given as per Appendix-4.
CHAPTER -V
Regulation - 26. Construction of Farm House Building in Agricultural Use Zone.
26.1 Minimum size of plot-Minimum
size of a plot for farm house shall not be less than 1.0 hectare.
26.2 Maximum coverage and FAR
|
(a)
|
Maximum permissible ground coverage for all types
of activity
|
10 percent
|
|
(b)
|
Maximum permissible FAR
|
0.15
|
|
(c)
|
Residential accommodation of watch and
ward/maintenance staff
|
15 percent of permissible FAR
|
|
(d)
|
Maximum height
|
10.0 m
|
|
(e)
|
Setbacks
|
Front/side abutting road 15.0 metre and all other
sides 9.0 metre
|
26.3 Other provisions
(a) The maximum permissible floor
area includes the area of mezzanine floor also.
(b) The maximum height of boundary
wall shall be 3.0 mtrs from external drain top.
(c) Running creeper or flowering
creeper will be planted all along the wall.
(d) Minimum 50 percent of the total
area of the farm house shall be under plantation/cultivation. At least 100
trees per hectares have to be planted out of which at least 50 percent shall be
evergreen trees.
(e) Basement within the outer walls
of the buildings equivalent to the area of ground coverage shall be allowed. In
the event of open areas falling within the outer walls of the buildings,
maximum area of the basement may be allowed equivalent to double the area of
the ground coverage.
(f) Minimum requirement for sanction
and completion shall be 25% of permissible FAR.
26.4 Water supply, sewerage and
drainage:
(a) In case of a plot for a farm
house having dwelling unit the owner thereof shall be responsible to make
lawful arrangements for potable water in the farm house.
(b) The owner shall be responsible to
provide drains in the farm house to be used for rain water and in case of dairy
farm, open or closed sanitary drains to clean sheds, as may be required by the
Authority.
(c) The owner shall be responsible to
provide septic tank with necessary dispersion trenches for disposal of human
and animal wastes in the farm house within his own premises.
26.5 Electrification
The owner of a farm house shall obtain electric
connection directly from the appropriate authority authorised for distribution
on such terms and conditions and at his own cost as decided by the appropriate
authority.
26.6 Other Provisions:
(1) No construction of any kind shall
be permitted beyond the building envelope (on setbacks) except
(i) A Chajja (projection) of maximum
width of 0.75 metre at lintel or roof level. No construction of any type or any
material shall be permitted over projections other than mentioned herewith.
(ii) Underground water tanks with top
flush with the adjoining ground level.
(iii) Watchman Shelters and Watch
Towers with following provisions:
(iv) No projection of watchman
shelters and watch towers shall be allowed outside the plot line.
(v) Maximum height of watchman
shelter shall be 4 metres and for watch towers 15 metres. Total area, as
mentioned below, under such shelters shall be split up in desired number of
watch man shelter and watch towers as follows:
|
Sr. No.
|
Plot Size
|
Total area for watchman shelter and watch tower
|
Maximum area under each watchman shelter
|
Maximum area under each watch tower
|
|
1
|
Up to 0.5 acres
|
15 square metre
|
15 square metre
|
5 square metre
|
|
2
|
Above 0.5 acres upto 10 acres
|
30 square metre
|
24 square metre
|
5 square metre
|
|
3
|
Above 10 acres upto 25 acres
|
45 square metre
|
24 square metre
|
5 square metre
|
|
4
|
Above 25 acres upto 50 acres
|
60 square metre
|
24 square metre
|
5 square metre
|
|
5
|
Above 50 acres for an additional 50 acres
|
An additional 10 square metre and part thereof
|
24 square metre
|
5 square metre
|
(vi) The following features shall be
permitted after leaving minimum 6 mtrs. open corridor for fire tenders.
(a) Metre room as per norms of
Electricity Authority.
(b) Open transformers without any
permanent enclosure keeping in view the necessary safety requirements.
(c) Other features as mentioned in
Table 3
(d) Rockery, well and well
structures, water pool, swimming pool (if uncovered), uncovered platform around
tree, tank, fountain, bench, chabutra with open top and unenclosed by side
walls, compound wall, gate, slide swing, culverts on drains.
(e) Any other feature, primarily
ornamental in nature, not enclosing or covering space of commercial use may be
permitted by the Chief Executive Officer on case to case basis.
(f) Open generator set, filtration
plant, Electrical distribution equipments, feeder pillars, telephone
distribution equipments may be permitted in open setback as a service utility
provided after leaving clear space for fire tender.
(2) Floor Area Ratio shall include
(i) Mezzanine
(ii) The shafts provided for lifts
shall be taken for covered area calculations only on one floor and included in
ground coverage.
(iii) Pergola, shall be counted towards
Floor Area Ratio if closed from three or more than three sides.
(iv) Metre room as per Electricity
Authority norms.
(3) Floor Area Ratio shall not
include:
(i) A cantilever projection at any
level (in setbacks) of a width of 0.75 metre. No construction of any type or
any material shall be permitted over projections.
(ii) Basement shall be for storage,
services and parking only. It shall not be more than permissible ground
coverage.
(iii) Basement, if put to any use other
than mentioned above, shall be included in the FAR of the building.
(iv) Stilt area of non-habitable
height 2.40 metres from bottom of beam proposed to be used for parking,
landscaping etc.
(v) Balconies (upto 1.5 metre width)
free from FAR may be projected in open setbacks provided 6 mtr clear space is
available for fire tender movement.
(vi) Other features as mentioned in
Table 3.
(vii) Rockery, well and well
structures, water pool, swimming pool (if uncovered), uncovered platform around
tree, tank, fountain, bench, chabutra with open top and unenclosed by side
walls, compound wall, gate, slide, swing, uncovered staircase (unenclosed and
uncovered on three sides except for 0.9 metre high railing/wall and open to
sky), overhead tanks on top of buildings, open shafts, culverts on drains.
(viii) Open ramps with no area enclosed
below it of usable height. If used for approach to the entrance of the
building, then the height as per requirement may be considered. The space under
the ramp shall not be used for any commercial purpose, however it can be
landscaped with approval of the Chief Executive Officer on case to case basis.
(ix) Any other feature purely
ornamental in nature and not enclosing or covering space of commercial use may
be permitted by the Chief Executive Officer on case to case basis.
(4) 15% of prescribed FAR shall be
added towards common areas, which shall include the following built structures.
The structures on ground will be counted in Ground Coverage
(1) Canopy projections of area as
mentioned in table 4, no construction of any type shall be permitted over the
canopy. Canopy, if cantilevered and no structure on it having a size of 2.4m x
4.5m shall not be counted in Ground Coverage.
(2) Loft up to maximum height of 1.5
metre.
(3) Air-conditioning plant,
electrical installation, generator room, water works, water tank etc.
(4) Watchmen/Security shelters and
watch towers
(5) Garbage shafts, lift shafts and
10 sq mtr lobby in front of each lift (excluding area of corridor beyond the
lift).
(6) Fire escape staircases
(7) Toilet blocks for visitors,
drivers, guards etc on ground floor only.
(8) Mumty, machine room for lifts.
(9) Cupboards upto a depth of 0.60
mtr and 1.80 mtrs. in length.
(10) Bay window upto a depth of 0.60
mtr and 2.0 m length.
(11) Sewage treatment plant, water
treatment plant, garbage collection centre Electric sub-station, service ducts.
(12) Covered walkways and pathways.
(13) Any other utilities and
facilities as decided by the Chief Executive Officer depending upon its
requirement.
(5) The Authority shall have a right
to impose such restriction and limitations as to the number of storey and
extent of height of the building as he considers fit where protected areas,
ancient or historical monuments lie within a radius of one and half kilo metre
from the boundary line of such buildings by recording the reasons.
(6) The height of basement shall be
maximum 1.5 metres upto bottom of the slab above the top of the drain. In case
the basement is flush with the ground level adequate light and ventilation
shall be ensured.
(7) Provision of following item in
building shall be mandatory for issue of completion certificate:
(i) Flooring;/i.e. hard surface and
completely finished floors for common areas.
(ii) Electrical wiring;
(iii) Plumbing work to be complete.
(iv) Parking and landscaping as per
Table no. 5 and Table no. 6 respectively or as per directions issued from time
to time whichever is higher;
(v) Number plate and illumination
board as per direction amended or direction issued from time-to-time;
(vi) Internal and external finishing
(Plastering may not be mandatory);
(vii) Boundary wall and gates shall be
mandatory;
(viii) Buildings shall be lockable i.e.
all external doors and windows shall be provided. In case grill is provided in
the windows the fixing of glass in the windows pane shall not be mandatory;
(ix) No violation should be there in
the overall building or site at the time of issue of occupancy certificate;
(x) Any other special provision as
mentioned in the lease deed;
(xi) In case of completion of whole
project, all temporary structures to be removed. In case if any special clause
is mentioned in the lease deed or Memorandum of Understanding then the
requirement mentioned in the same shall be applicable.
CHAPTER-VI
Regulation - 27. Construction of Building in Village abadi.
Notwithstanding anything contained in these
regulations herein after mentioned, The ownership and area of village abadi
shall be determined by the land department of the Authority, The construction
of buildings in village abadi shall be regulated as follows.
27.1 Setback
|
Plot Size
|
Front setback
|
Rear setback
|
Side setback for corner
|
|
Up to 200 square metre
|
2.0 metre
|
...
|
1.2 metre
|
|
201-500 square metre
|
3.0 metre
|
...
|
1.2 metre
|
|
501-1000 square metre
|
4.5 metre
|
3.0 metre
|
3.0 metre
|
|
1001-2000 square metre
|
10 metre
|
4.5 metre
|
4.5 metre
|
|
2001-4000 square metre
|
12 metre
|
6.0 metre
|
6.0 metre
|
|
Above 4000 square metre
|
15 metre
|
6.0 metre
|
6.0 metre
|
*Side setbacks will be applicable for all plots
(including corner plots) on both sides for sizes above 500 square metres.
27.2 Covered Area
(a) Ground floor
|
Plot Size
|
Maximum permissible ground coverage
|
|
Upto 200 square metre
|
80%
|
|
201-500 square metre
|
75%
|
|
501-1000 square metre
|
70%
|
|
1001-2000 square metre
|
65%
|
|
2001-4000 square metre
|
60%
|
|
Above 4000 square metre
|
55%
|
(b) First floor- equivalent to
maximum permissible ground coverage.
(c) Barsati floor- 50 percent of the
ground floor including mumty.
(d) Maximum Height 1 1.0 mtrs.
27.3 NOTE:-
Basement shall be permitted within the building
line only i.e. area after leaving setbacks. The internal height of the basement
(floor to ceiling) shall be minimum 2.4 metre and maximum 4.0 metre and shall
be used for parking and storage only.
All formalities as per regulation No. 6.1 will have
to be completed for construction of basement.
27.4. Use of the Plot
On plots in village abadi which have not been
notified for acquisition under the Land Acquisition Act or have been
recommended for de-notification under land acquisition act by the competent
authority. Non - Residential activities shall be allowed maximum up to 50
percent of the total permissible ground coverage on payment of prescribed
charges in clause 27.9
27.5 Fire safety requirements
shall be as per National Building Code and U.P. Agni Nivaran Adhinam(Act No. 6
of 2005)
27.6 Items permissible in the
setback and calculation of FAR shall be carried out as per regulation 24.0.
27.7 Provisions of parking,
loading and unloading spaces
(a) Parking space to be provided for
motor vehicles, shall not be less than 20 square metre in open area (under
stilts: 30 square metre) and for scooters and cycles the parking spaces
provided shall not be less than 3 square metre and 1.40 square metre respectively.
(b) Parking space for vehicles shall
be provided as per table-5 annexed to these regulations.
27.8 Explanation:-
Boundary wall height provision shall be as per
prevailing directions issued by Authority from time to time.
27.9 Fees for Conversion of use
Development charge shall be charged only on
commercial conversions up to a maximum conversion of 50% of plot area, which
shall be levied as follows:
(i) On roads of Right of way upto
12.00 metre -prevailing residential rate revised from time to time.
(ii) On roads of Right of way above
12.0 metre and up to 18.0 metres. 1.25 times of the prevailing residential rate
revised from time to time.
(iii) On roads of Right of way above
18.0 metre and up to 24.0 metres. 1.50 times of the prevailing residential rate
revised from time to time.
(iv) On roads of Right of way above
24.0 metre and up to 45.0 metres. 100% of the prevailing reserved commercial
rate as per plot size, revised from time to time minus the land cost.
(v) For corner plot 5% additional of
above mentioned charges shall be levied.
(vi) For safety requirements shall be
as per National Building Code and Uttar Pradesh Fire Act.
(vii) Items permissible in the setback
and calculation of Floor Area Ratio shall be done as per clause (A) of
regulations 24.1.
(viii) Provisions of parking, loading
and unloading spaces:
(a) Parking space to be provided for
motor vehicles, shall not be less than 20 square metre in open area (under
stilts; 30 square metre) and for scooters and cycles the parking spaces
provided shall not be less than 3 square metre and 1.40 metre respectively.
(b) parking space for other vehicles
shall be provided as per table-5.
27.10 Fees for Sanction and
completion of building plans:-
fees shall be calculated as per regulation 10
CHAPTER-VII
Regulation - 28. Construction on Plots allotted to the farmers against land acquisition (5% or 6% or 7% as the case may be) in planned village abadi Expansion scheme or in sectors.
28.1 Setbacks
|
Plot Size
|
Front setback
|
Rear setback
|
Side setback for corner
|
|
Up to 200 square metre
|
2.0 metre
|
...
|
1.2 metre
|
|
201-500 square metre
|
3.0 metre
|
...
|
1.2 metre
|
|
501-1000 square metre
|
4.5 metre
|
3.0 metre
|
3.0 metre
|
|
1001-2000 square metre
|
10 metre
|
4.5 metre
|
4.5 metre
|
|
2001-4000 square metre
|
12 metre
|
6.0 metre
|
6.0 metre
|
|
Above 4000 square metre
|
15 metre
|
6.0 metre
|
6.0 metre
|
*Side setbacks will be applicable for all plots
(including corner plots) on both sides for sizes above 500 square metre.
28.2 Covered Area
(a) Ground floor
|
Plot Size
|
Maximum permissible ground coverage
|
|
Upto 200 square metre
|
80%
|
|
201-500 square metre
|
75%
|
|
501-1000 square metre
|
70%
|
|
1001-2000 square metre
|
65%
|
|
2001-4000 square metre
|
60%
|
|
Above 4000 square metre
|
55%
|
(b) First floor- equivalent to
maximum permissible ground coverage.
(c) Barsati floor- 50 percent of the
ground floor including mumty.
(d) Maximum Height 11.0 mtrs.
28.3 Note
Basement shall be permitted within the building
line only i.e. area after leaving setbacks. The internal height of the basement
(floor to ceiling) shall be minimum 2.4 metre and maximum 4.0 metre and shall
be used for parking and storage only.
All formalities as per clause No. 6.1 will have to
be completed for construction of basement.
28.4 Use of the Plot
On plots allotted in planned village expansion
scheme or in sectors (5% or 6% or 7%): Non - Residential activities shall be
allowed maximum upto 50 percent of the total permissible ground coverage on
payment of prescribed charges and it should be a part of the following
activities-
(1) Dharmshala/Night shelter/baratghar
(2) Dispensary/clinic/laboratory
(3) Hostel
(4) Guest House/lodging house
(5) Motor garage and workshop
(6) Office for professionals - out of
which minimum 50% of the space shall be used for self use.
(7) Restaurant
(8) Vending booth/kiosks
(9) Bank
(10) Post Office
(11) Telegraph Office
(12) Creche and Day-care centre
(13) Retail shop
(14) Telecommunication tower (only
ground based)
No activity whatsoever other than those mentioned
above shall be allowed. Allottees under this category will intimate in advance
and provide an undertaking to the Authority that the proposal is in-conformity
to the bye-laws and other regulations prevalent at that time.
28.5 Fees for Conversion of use
(i) On roads of Right of way up to
12.00 metre -prevailing residential rate revised from time to time.
(ii) On roads of Right of way above
12.0 metre and up to 18.0 metres. 1.25 times of the prevailing residential rate
revised from time to time.
(iii) On roads of Right of way above
18.0 metre and up to 24.0 metres. 1.50 times of the prevailing residential rate
revised from time to time
(iv) On roads of Right of way above
24.0 metre and up to 45.0 metres. 2.00 times of the prevailing reserved
residential rate as per plot size.
(v) For corner plot 5% additional of
above mentioned charges shall be levied.
28.6 Other Provisions
(i) Fire safety requirements shall be
as per National Building Code and Uttar Pradesh Agni Nivaran Adhinam(Act No. 6
of 2005)
(ii) Items permissible in the setback
and calculation of Floor Area Ratio shall be done as per regulation 24.
(iii) Provisions of parking, loading
and unloading spaces:
(a) Parking space to be provided for
motor vehicles, shall not be less than 20 square metre in open area (under
stilts; 30 square metre) and for scooters and cycles the parking spaces
provided shall not be less than 3 square metre and 1.40 metre respectively.
(b) parking space for other vehicles
shall be provided as per table-5.
(iv) Boundary wall height provision
shall be as per prevailing direction issued by the Authority from time to time.
28.7 Fees for Sanction and
completion of building plans:-
fees shall be calculated as per regulation 10.
28.8 Provisions regarding
Commercial activities
(1) On plots situated along the 30.0m
and above wide roads, commercial activities shall be allowed in addition to the
activities as mentioned in regulation 28.4.
(2) The activities as mentioned in
sub regulation (1) above and in regulation 28.4 shall also be allowed the
allotted plots of those farmers whose land was acquired and due any special
circumstances a part of land has been returned to as per lease back policy of
the Authority.
CHAPTER-VIII
Regulation - 29. Purchasable Far.
29.1 Note:-
Provision of purchasable FAR in Group Housing,
Commercial, Institutional, Industrial, Sport and amusement complex,
recreational greens and Low Density Sports plot may be considered, where:
(i) The Plots exist on 24 mtrs. and above wide road.
(ii) The construction has not started.
OR
The allottee wants to construct a new additional
building within the limits of permissible ground coverage.
OR
The allottee wants to construct new building on the
vacant plot.
OR
The allottee has already constructed building
within purchasable F.A.R limits
OR
Purchasable F.A.R may be allowed on minimum 18.0
mtrs. and above road width for institutional and industrial use.
Note: The Purchasable FAR shall be allowed up to
the maximum limit of the applicable FAR in the Building Regulations.
29.2 Purchasable FAR shall be allowed with the following provisions/conditions:-
(i) No construction shall be allowed beyond the limit of maximum permissible
ground Coverage.
(ii) Parking facilities shall be provided within the plot as per the
provisions of the building bylaws.
(iii) No objection certificate from the Airport Authority of India/Competent
Authority shall be obtained for the height of the building.
(iv) Structural design duly checked and verified by the
I.IT/N.I.T./Government Engineering College shall be submitted along with the
proposal in case where additional floors are being proposed.
(v) No objection certificate from Fire Safety and Environmental Clearance shall
be obtained from the Competent Authorities.
(vi) Purchasable FAR shall be applicable only on the basis of assessment of
planned and available physical infrastructure.
(vii) Use of purchasable FAR shall be governed by the terms and conditions of
lease deed.
(viii) In case where purchasable FAR is allowed, the Authority shall permit
increase in the height of building as per requirement.
(ix) Additional Proportionate residential units shall be allowed on the
purchasable FAR for Group Housing.
Note:-
(i) Purchasable FAR is an enabling provision. It shall not be allowed to any
Allottee as a matter of right.
(ii) With the consideration of Traffic density, conditions of approach road,
availability of physical infrastructure, distance from the protected area and
heritage sites or in the light of planning the Authority may identify the
zones/areas where purchasable FAR shall not be allowed.
(iii) In case of mixed land use permitted in any pocket/plot:
(a) Permissible FAR for various uses shall be as applicable for respective
use including the purchasable FAR.
(b) The total FAR in the pocket/plot shall be subject to the overall
permissible FAR for the pocket/plot.
(c) Purchasable FAR shall be calculated on the basis of the FAR of the
individual uses within that pocket/plot.
29.3 Calculation Method for the rate of charges of Purchasable FAR:-
Rate assessment for purchasable FAR shall be
calculated in proportion to the land requirement for additional built up area.
The Fraction of land value shall be charged from the allottee on the basis of
following formula:-
C=Le x Rc x P
C=Charge
Le=Proportionate Land required against purchasable
FAR
i.e. Fp x 100/FAR
Fp = Allowed Additional covered area(sq.mtr.) as
per purchasable FAR.
FAR= Permissible Floor Area Ratio as per Building
Regulations.
Rc= Prevailing sector rate or allotment rate of
related plot (on the basis of auction/sealed bid) whichever is higher.
P=Value of purchasable Factor is as follows:-
Group Housing =0.40
Commercial =0.60
Institutional/Institutional green* =0.30
Industrial =0.30
Green/sport/recreational Areas =0.20
29.4 Note:-
*(i) The purchasable FAR in institutional green plot
shall only be permissible for the institutional use in the plot.
(ii) The purchasable FAR shall be allowed to a
maximum permissible FAR allowed for the particular use above the constructed
building. If the allottee has done the construction before sanctioning, the
compounding charge of un-sanctioned area shall be payable at the rate of Rs.
200/-per sqmtr. This penalty shall be over and above the fee charged for
purchasable FAR. In case the construction is beyond the limit of purchasable
F.A.R the allottee will have to first remove the extra construction beyond
permitted FAR, then allottee may be allowed the extra purchasable F.A.R.
(iii) The Authority may also fallow additional
ground coverage with purchasable F.A.R upto the maximum limit of 40% in
commercial plots of more than 5000 sq. mtr. area on the basis of additional charges.
Additional Charges for Purchasable Ground Coverage
shall be calculated as follows:
C= L x 0.30 x R
C= Cost of additional purchasable ground coverage
L= Land required under ground cover for additional
ground coverage
R= Rate of land per sq.mt. (current reserve price
or auction/bid/allotment rate whichever is higher) 0.30 is a constant factor
for purchasable ground coverage. However, additional coverage will not be
considered in the setback area.
(iv) Increase in FAR of industrial plots prior to
the commencement of these regulations shall continue to be allowed free of
cost. But the increase of FAR of industrial plots notified in these Regulations
shall be allowed on purchasable basis. Purchasable FAR may be allowed up to 2.0
FAR in the Industrial plots.
CHAPTER - IX
Regulation - 30. Provisions of parking, loading and unloading spaces.
Parking may be provided in open, under stilt, or
underground in basements or separate block plots for multi level parking
through mechanized methods or conventional ramps. Other option in selected
areas is through podium parking. Creation of underground parking below parks
and open spaces without disturbing the green areas on the surface may be
considered only in exceptional cases as per policy approved by the Authority.
Surface parking shall be allowed in setback after leaving clear space of 7.5
mtrs., and fulfilling the requirement of tree plantation and Fire Tender
movement.
30.1 Other Provisions
(1) Multi-level Parking plots-
(i) Multi-level parking facility
should preferably be developed in the designated parking spaces/plots.
(ii) In order to compensate the cost
of multi level parking in designated areas and also to fulfill the growing need
of parking spaces within urban areas, a maximum 25% of ground floor covered
area may be utilized as commercial space. The balance covered area may be
utilized on top floors for office use on a plot designated or planned for
parking facility.
(iii) In addition to the required
parking spaces for maximum permissible FAR, 3 times additional space for
parking component shall be provided.
(iv) Maximum ground coverage shall be
70%.
(v) For development of multilevel
parking, models should be worked out to encourage the private sector initiative
without commercial component.
(vi) Multi level parking facility
shall be allowed in all type of plots.
(2) Basement Parking
(i) In plots larger than 10000 sq.
mtrs., the basement shall be allowed upto minimum setback of 6.0 mtrs. There
will be no restriction on the number of levels of basement subject to
mechanical ventilation as per provisions in National Building code - 2005,
water proofing and structural safety. Evergreen trees shall have to be planted
in setback as per landscaping norms of these byelaws.
(ii) Height of first basement above
ground level will be maximum 1.5 mtrs below the roof slab. Where stilt or
podium parking is permitted, the first basement roof will be levelled with the
ground and the roof slab of the extended basement up to envelop line shall be
designed for the fire tender load.
(iii) The height of basements from
floor to ceiling shall be maximum up to 4.5 mtrs.
(iv) The ramp within setbacks shall be
permissible subject to free and convenient movement of fire tender.
(v) Adequate fire safety, light and
ventilation and air change through mechanical means shall be provided as per
provisions in National Building Code, 2005.
(vi) The basements may be used only
for parking, services like fire rooms and storage of non-hazardous materials.
(3) Podium Parking
For adequate parking space, podium parking up to
maximum two floors may be permitted within the envelope line, only for parking,
with the following conditions;
(i) Minimum plot area = 10000 sq
mtrs.
(ii) Minimum width of the road = 18
mtrs.
(iii) Minimum set back at the ground
level will be 7.5 mtrs. all around where stilt and one storey podium will be
permitted, however, other floors of podium parking may be permitted with larger
set back.
(iv) The height of one level of podium
will be maximum 2.4 mtrs. from floor to the bottom of beam.
(v) Podium levels will not be
enclosed by any material on the outer periphery except with one metre high
metal Jali/mesh for safety.
(vi) Adequate sprinklers, exits, ramps
and fire fighting provisions as per provisions in National Building Code - 2005
will be provided.
(vii) Structural safety measures as per
BIS codes and for fire tender movement will be ensured.
(viii) Ramp for podium shall not be
allowed in the setback.
(ix) Services and storage shall be
allowed upto the extent of permissible ground coverage.
(4) Mechanised Parking
(i) Mechanized multi level parking
will be permitted subject to the following;
(ii) Minimum plot size = 1000 sq.
mtrs.
(iii) Minimum width of road = 18 mtrs.
(iv) ECS = 18 sq. mtrs. or as per the
design and Technology.
(v) Clear Height of one level = 2.1 mtrs.
(vi) Adequate safety measures for
mechanical equipments.
(vii) Backup of electricity through
automatic generators.
(viii) The company shall ensure proper
maintenance, structural safety equipment and machinery.
(5) Underground Parking
Parking facilities can be created under the open
spaces/parks (except heritage park), playground without disturbing the green
areas on the surface and surrounding environment. The approvals from the
concerned Authority are mandatory after following due process of public hearing
before taking up such works. The guidelines for approval are as follows;
(i) Minimum area of open
spaces/park/playground = 5000 sq. mtrs.
(ii) Minimum width of abutting road =
18 mtrs.
(iii) Up to 50% of the area to be
utilized for underground parking with minimum two basements.
(iv) Ramps to be provided with not
more than 1:10 slope.
(v) Maximum height from the road
level shall be 0.5 mtrs with provision for mechanized light and ventilation.
(vi) Minimum set back from the
boundary of the park will be 1.5 mtrs for the purpose of staircase and ramps.
(vii) Fire & structural safety
measures shall be as per National Building Code, - 2005.
(viii) Minimum depth of the earth shall
be 0.5 mtrs. for planting shrubs and grass.
(ix) Adequate drainage for irrigation
facilities and for water proofing shall be mandatory.
(x) The Authority may consider to
relax the minimum area limit depending upon the requirement in a particular
area.
(a) When parking space is to be
provided for motor vehicles, it shall not be less than 20 square metre in open
area and 30 square metre in basement and in stilts and for scooters and cycles
the parking spaces provided shall not be less than 3 square metres and 1.40
square metres respectively.
(b) For buildings of different types,
parking space for vehicles shall be provided as specified in table No. 5-6.
Extended Basement: The basement shall be allowed within the setback only for
parking purpose all around the plot boundary after leaving a minimum setback of
6.0 mtrs. For fire tender movement. The top of the slab shall be flushed with
the ground level and the roof shall be designed to take the load of the fire
tender with mechanized ventilation. Enclosure:- 1. Tables (1 to 6) 2. Appendix
(1 to 12)
TABLE NO. 1
(See regulation 24.1)
"This content is in vernacular language.
Kindly email us at info@legitquest.com for this content."
TABLE NO. – 2
(See regulation 24.2, 24.3, 24.4,
24.5, 24.6, 24.7)
Setbacks for all category and
uses of plots other than individual residential Plots
|
S.No.
|
Plot Size (in square metre)
|
Front (in metre)
|
Rear (in metre)
|
Side (1) (in metre)
|
Side (2) (in metre)
|
|
1.
|
Up to 150
|
3.0
|
1.5
|
0
|
0
|
|
2.
|
Above 151 upto 300
|
3.0
|
3.0
|
0
|
0
|
|
3.
|
Above 301 upto 500
|
4.5
|
3.0
|
3.0
|
0
|
|
4.
|
Above 501 upto 2000
|
6.0
|
3.0
|
3.0
|
3.0
|
|
5.
|
Above 2001 upto 6000
|
7.5
|
6.0
|
4.5
|
4.5
|
|
6.
|
Above 6001 upto 12000
|
9.0
|
6.0
|
6.0
|
6.0
|
|
7.
|
Above 12001 upto 20,000
|
12.0
|
7.5
|
7.5
|
7.5
|
|
8.
|
Above 20,001 upto 40,000
|
15.0
|
9.0
|
9.0
|
9.0
|
|
9.
|
Above 40,001
|
16.0
|
12.0
|
12.0
|
12.0
|
Notes:
(1) Specific setbacks shall be as per
scheme/layout/zonal plan prepared by the Authority whenever such a plan is
prepared by the Authority.
(2) In case the permissible coverage
is not achieved within setbacks, the setbacks of the preceding category may be
followed.
TABLE NO. – 3
(See regulation 24.2, 24.3, 24.4,
24.5, 24.6, 24.7)
Features permitted in the
setbacks of the plots after leaving 6.0m clear space for fire tender
|
S.No.
|
Features
|
Description
|
|
1.
|
Decorative
|
Columns purely decorative and not load bearing
shall be
|
|
|
Column
|
permitted in setback. Such columns of any
material and number shall be permitted but maximum size of each column shall
not exceed 0.30 mtrs x 0.30 mtrs
|
|
2.
|
Buttresses
|
Buttresses, any number, shall be permitted in
setback up to maximum width of 0.750 mtrs in setback.
|
|
3.
|
Moulding,
|
Murals, moulding and cornices if provided along
under any
|
|
|
Cornices and
|
projection shall be permitted upto a maximum
width of 150
|
|
|
Murals
|
milli metre over and above the maximum
permissible dimensions of a projection or a canopy.
|
|
4.
|
Planters and Sun
|
Projection in form of planter, cantilevered fins,
egg crates
|
|
|
Control Devices
|
and other sun control devices shall be permitted
in setback upto maximum width of 0.750 metre. Maximum depth of such planters
shall not exceed 0.600 metre.
|
|
5.
|
Jali
|
Jali of any material shall be permitted over
projections which are primarily meant to cover window Air-conditioning units
and dessert cooler. Maximum width of such jalies shall not be more than 0.75
mtrs.
|
|
6.
|
Casing Enclosure
|
Casing/enclosures of any material to cover rain
water pipe
|
|
|
to cover Rain
|
shall be permitted in setback upto depth of
maximum
|
|
|
Water pipe
|
0.50 mtrs and maximum width of 0.75 mtrs
|
TABLE NO. – 4
(See regulation 24.2, 24.3, 24.4,
24.5, 24.6, 24.7)
Area under canopy in buildings
other than residential buildings
|
S.No.
|
Plot size (in square metre)
|
Maximum area under canopy (in sq mtrs.)
|
|
1.
|
Upto 150
|
Nil
|
|
2.
|
Above 150 upto 300
|
12 (only in side setback)
|
|
3.
|
Above 300 upto 500
|
25
|
|
4.
|
Above 500 upto 2000
|
40
|
|
5.
|
Above 2000 upto 4000
|
55
|
|
6.
|
Above 4000 upto 10,000
|
70
|
|
7.
|
Above 10,000 upto 20,000
|
85
|
|
8.
|
Above 20,000 upto 40,000
|
100
|
|
9.
|
Above 40,000
|
115
|
Note:
Minimum width of canopy shall be 1.8 mtrs.
TABLE NO. – 5
Provision of Parking Requirement
|
SI. No.
|
Building/plot
|
Parking space
|
|
1.
|
(a) Group Housing
|
One ECS/parking space per 80 square metres of
permissible FAR area.
|
|
|
(b) Hostel, Lodges, Guest house Hotel.
|
One parking space for every 2 guest rooms.
|
|
2.
|
Educational Building
|
One parking space for every 100
|
|
square
|
|
metres of permissible FAR area.
|
|
|
(a) IT/ITES, Offices,
|
One parking space for 50 square metre of
permissible FAR area.
|
|
|
and Institution
|
|
|
|
(b) Auditorium
|
One Parking space per 15 seats
|
|
|
(c) Bus parking
|
One bus parking per 750 square metre of
permissible FAR area.
|
|
|
(d) Off street parking
|
Higher Secondary School 4.5 mtrs. off-street
parking depth in the entire frontage with boundary wall shifted back and
front set back will be considered from property line and in other
institutions upto 4.5 mtrs. in half the width of the front of the plot would
be required for providing off-street parking on roads of 18.0 mtrs or more
width.
|
|
|
e) Residential area
|
One parking space per 150 sq mtrs. of permissible
FAR area, in plot size of 112 sq mtrs. and above.
|
|
3.
|
Medical
|
One parking space for every 65 sq mtrs. of
permissible FAR area. One ambulance for every 375 sq mtrs of permissible FAR
area.
|
|
4.
|
Commercial
|
One parking space for 30 sq mtrs of permissible
FAR area.
|
|
5.
|
Industrial
|
One parking space per 100 sq mtrs of permissible
FAR area.
|
|
6.
|
Storage
|
One parking space for 100 sq mtrs of permissible
FAR area.
|
|
7.
|
Loading/Unloading
|
One parking space for every 100 sq mtrs. for
industries and storage building
|
|
8.
|
Multiplex/Cinema
|
One parking space per 15 seats.
|
|
9.
|
Religious
|
One parking space per 100 sq mtrs of permissible
FAR area.
|
|
10.
|
Utilities (Fire Station, Police
Stations, Post Office, Taxi Stand etc.)
|
One parking space per 100 sq mtrs of permissible
FAR area.
|
|
11.
|
Recreational
|
One parking space per 50 sq mtrs of permissible
FAR area.
|
|
12.
|
One ECS
|
=13.75 sqmtrs,
|
|
13.
|
Area Requirement
|
30 sq mtrs. per ECS in
basement/stilt/podium/covered parking and 20 sq mtrs for surface parking
|
Note:
(I) Notwithstanding anything
contained in these directions/regulations the Chief Executive Officer may where
having regard to the features of a particular sector and the width of a road
abutting any building/plot and the master plan consider it expedient to do so
order for the preparation of architectural control detailed drawing for any of
all the major projects specifically, especially of non residential character
which may or may not deviate partly or wholly from the provisions of these
regulations. For such purpose, Chief Executive Officer may constitute a
committee, which shall submit its report to him for final decision.
(II) Helipad may be permitted on the
roof top of buildings above 60 mtrs. height subject to the clearance from
Airport Authority and structural safety from I.I.T/N.I.T.
(III) Development of parking facilities
may be permitted proportionately on the basis of proposed phase wise
development. However, provision of parking facilities has to be made on the
basis of maximum permissible F. A.R.
(IV) Parking norms are revised from
time to time. Parking facilities have to be provided on the basis of revised
norms for new proposed construction. Parking facility developed on the basis of
old norms for old construction may be allowed to continue. If no parking
facility has been developed, provisions have to be made on the basis of new
norms for the entire old and proposed construction.
TABLE NO. – 6
Provisions for Landscaping
(1) (a) Institutional, commercial,
office/Industrial units/group housing, farm house shall be required to plant a
minimum number of trees in their premises as follows.
|
Plot size (in square metre)
|
Number of trees required
|
Minimum open space to be kept for landscaping
|
|
Upto 2000
|
One tree per 100 square metre of open space out
of which minimum 50 percent to be in the category of evergreen trees.*
|
25 percent of open area. In case of industrial
plots no soft landscaping is required
|
|
Above 2000 to 12000
|
One tree per 100 square metre of open space out
of which minimum 50 percent trees to be in the category of evergreen trees.
|
25 percent of open area
|
|
More than 12000-
|
One tree per 100 square metre of open space out
of which minimum 50 percent to be in the category of evergreen trees.
|
50 percent of open area
|
(b) In case of plotted
development in group housing plantation provision shall be as per Landscape
Master Plan and following norms shall be followed.
(i) On 18.0 metre and 24.0 metre wide
road, alternate variety of evergreen and ornamental trees shall be planted @
7.5 metre centre to centre.
(ii) On road upto 12 metre ornamental
trees will be planted @ 5 metre centre to centre of single variety in each
pocket.
(c) Recreational, Institutional Green:
In addition to the requirement as mentioned in clause (a) detailed landscape
plan will have to be got approved by the Authority as per specification in
Landscape Master Plan and landscape manual approved by the Authority.
(2) Residential plots other than
group housing (flatted):-
(i) One tree in every plot for plot
size upto 120 square metre.
(ii) Two trees in every plot for plot
size above 120 and upto 300 square metre.
(iii) One tree additional in every
100sqm for plot above 300 square metre.
(3) The minimum height of plantation
of sapling should be 3.6 mtrs at the time of occupancy.
* Evergreen Tree: Tree that remains green for most
part of the year and sheds leave slowly throughout the year, having height more
than 2.0 mtrs, with a well distinguished trunk,