Loading...

Lead Stabilizer In Polyvinyl Chloride (Pvc) Pipes And Fittings (Amendment) Rules, 2022

Lead Stabilizer In Polyvinyl Chloride (Pvc) Pipes And Fittings (Amendment) Rules, 2022

Lead Stabilizer In Polyvinyl Chloride (Pvc) Pipes And Fittings (Amendment) Rules, 2022

 

[04 May 2022]

 

G.S.R. 334(E).-In exercise of the powers conferred by sections 3 and 6 of the Environment (Protection) Act, 1986 (29 of 1986) read with rule 13 of the Environment (Protection) Rules, 1986, the Central Government hereby makes the following rules to amend the Lead Stabilizer in Polyvinyl Chloride (PVC) Pipes and Fittings Rules, 2021, namely.

Rule - 1. Short title and commencement.

 

(1)     These rules may be called the Lead Stabilizer in Polyvinyl Chloride (PVC) Pipes and Fittings (Amendment) Rules, 2022.

 

(2)     They shall come into force six months from the date of notification in the Official Gazette.

Rule - 2.

 

In the Lead Stabilizer in Polyvinyl Chloride (PVC) Pipes and Fittings Rules 2021 (hereinafter referred to as the said rules), in rule 2,-

 

(a)      in sub-rule(1), for the words, brackets and figure "provided in column (3)", the words, brackets and figure "provided in column (4)", shall be substituted;

 

(b)      for sub-rule (2), the following sub-rule shall be substituted, -

 

(i)       The manufacturer shall submit water test report of pipes and fittings carried out by authorised agencies for testing as per sub-rule (1) of rule 4, to respective State Pollution Control Board or Pollution Control Committee in accordance with the consent to operate granted by respective State Pollution Control Board or Pollution Control Committee subject to the provision of the Water (Prevention and Control of Pollution) Act, 1974 (6 of 1974):

Provided that the manufacturer having valid licence from Bureau of Indian Standards for manufacturing of all such Polyvinyl Chloride Pipes and Fittings, and having all such Polyvinyl Chloride Pipes and Fittings marked with "Standard Mark" in accordance with the specification provided in the Licencse issued by the Bureau of Indian Standards, shall be exempted from submission of such test report.

(ii)      Every manufacturer and every importer of Polyvinyl Chloride Pipes and Fittings for every product under the respective Category A, B, and C specified in the Schedule shall comply with the conditions mentioned in that Schedule with respect to IS code of Bureau of Indian Standard or equivalent which are presently available or shall be developed in the future.

 

Explanation.- For the purposes of this rule and rule 3, "manufacturer" means manufacturer of Polyvinyl Chloride Pipes and Fittings situated within the territory of India or outside the territory of India.

 

Rule - 3.

 

In rule 3 of the said rules, in sub- rule (3), for the words "A Panel", the words "A Panel including a representative from manufacturer", shall be substituted.

Rule - 4.

 

In rule 4 of the said rules, for sub- rule (1), the following sub-rule (I) shall be substituted namely.

 

(I)      "The Laboratories accredited by National Accreditation Board for Testing and Calibration Laboratories shall be authorised to carry out such tests as are necessary to ascertain the compliance of rule 2".

Rule - 5.

 

In the said rules, for the Schedule, the following Schedule shall be substituted, namely.

 

"SCHEDULE

 

(See rules 2 and 5)

 

LIST OF PVC PIPES AND FITTINGS AND CORRESPONDING INDIAN STANDARDS PUBLISHED BY THE BIS

 

Sl. No.

Item

Indian Standard No. and Titlei

Lead extraction limits as on date of notification

Date of application of prohibition

(1)

(2)

(3)

(4)

(5)

CATEGORY A:Use of PVC Pipes and Fittings for Potable Water Supply

A. 1.

Unplasticised PVC pipes for Potable water supplies

Type A of IS 4985:2021 Unplasticised PVC pipes for water supplies - Specification                                      (fourth revision)

1      ppm      (first extraction)           and 0.05 ppm (third extraction)

After one year from the date of publication of these rules

A. 2.

Unplasticized polyvinyl chloride (PVC-U) screen and casing pipes for bore/tubewells

IS 12818:2010 Unplasticized polyvinyl chloride (PVC-U) screen and casing pipes for bore/tubewells                       - Specification             (second revision)

1      ppm      (first extraction)           and 0.05 ppm (third extraction)

 

 

-Do-

A. 3.

Chlorinated polyvinyl chloride (CPVC) pipes for potable hot and cold water distribution supplies

IS 15778:2007 Chlorinated            polyvinyl chloride (CPVC) pipes for potable hot and cold water distribution supplies – Specification

1      ppm      (first extraction)           and 0.05 ppm (third extraction)

 

 

-Do-

A. 4.

Oriented unplasticized polyvinyl chloride (PVC-O) pipes for water supply

IS 16647:2017 Oriented            unplasticized polyvinyl chloride (PVC-O) pipes for water supply - Specification

1      ppm      (first extraction)           and 0.05 ppm (third extraction)

 

-Do-

A. 5.

Fabricated PVC-U fittings for potable water supplies

IS     10124     (Parts     1     to 13):2009 Fabricated PVC-U fittings for potable water supplies Specification             (second revision)

1      ppm      (first extraction)           and 0.05 ppm (third extraction)

 

-Do-

A. 6.

Injection moulded PVC socket fittings with solvent cement joints for water supplies

IS 7834(Parts 1 to 8):1987 Specification for injection moulded PVC socket fittings with solvent cement joints for water supplies (first revision)

1      ppm      (first extraction) and 0.05 ppm (third extraction)

 

-Do-

A.7.

Chlorinated polyvinyl chloride (CPVC) fitting for potable hot and cold water distribution supplies

IS 17546:2021 Chlorinated polyvinyl chloride (CPVC) fitting for potable hot and cold water distribution supplies – specification

1 ppm (first extraction) and 0.05 ppm (third extraction)

 

 

-Do-

 

CATEGORY B: Use of PVC Pipes and Fittings in Agriculture and in Suction and Delivery Lines of Agricultural Pumps and Rain Water Systems

(1)

(2)

(3)

(4)

(5)

B. 1.

Unplasticized PVC pipes                              for agriculture

Type B of IS 4985:2021 Unplasticized PVC pipes for water supplies - Specification                                      (fourth revision)

1      ppm      (first extraction)           and 0.05 ppm (third extraction)

After three years from the date of publication of these rules

B. 2.

Unplasticized PVC pipes for use in suction                            and delivery lines of agricultural pump sets

IS 12231:1987 Specification                      for unplasticized PVC pipes for use in suction and delivery lines of agricultural pump sets

1      ppm      (first extraction)           and 0.05 ppm (third extraction)

 

-Do-

B. 3.

UPVC pipe fittings to be used with the UPVC pipes in the suction                            and delivery   lines   of agricultural pumps

IS 13593:1992 Specification for UPVC pipe fittings to be used with the UPVC pipes in the suction and delivery lines of agricultural pumps

1      ppm      (first extraction)           and 0.05 ppm (third extraction)

 

-Do-

B. 4.

Flexible            PVC pipes                   polymer reinforced thermoplastic hoses for suction and delivery lines of          agricultural pumps

IS 15265:2003 Flexible PVC pipes polymer                                reinforced thermoplastic hoses for suction and delivery lines of agricultural pumps - Specification

1      ppm      (first extraction)           and 0.05 ppm (third extraction)

 

 

-Do-

B. 5.

Unplasticized polyvinyl chloride (PVC-U) pipes for soil and discharge system for inside and                      outside buildings including ventilation and rain water system

IS 13592:2013 Unplasticized polyvinyl chloride (PVC-U) pipes for soil and discharge system for inside and outside buildings                  including ventilation and rain water system – Specification (first revision)

1      ppm      (first extraction)           and 0.05 ppm (third extraction)

 

 

-Do-

B. 6.

Unplasticized polyvinyl chloride (UPVC) injection moulded      fittings for soil and waste discharge     system for      inside                  and outside           buildings including ventilation and rain water system

IS 14735:1999 Unplasticized polyvinyl chloride (UPVC) injection moulded fittings for soil and waste discharge system for inside and outside buildings including ventilation and rain water system - Specification

1      ppm      (first extraction)           and 0.05 ppm (third extraction)

 

 

-Do-

CATEGORY C: Use of PVC Pipes and Fittings for Drainage and Sewarage System

(1)

(2)

(3)

(4)

(5)

C. 1.

Unplasticized polyvinyl chloride UPVC single wall corrugated      pipes for drainage

IS 9271:2004 Unplasticized polyvinyl chloride UPVC single wall corrugated pipes for drainage - Specification (first revision)

1      ppm      (first extraction)           and 0.05 ppm (third extraction)

After four years from the date of publication of these rules

C. 2.

Unplasticized non- pressure polyvinyl chloride   (PVC-U)

IS 15328:2003 Unplasticized non-pressure polyvinyl chloride (PVC-U)

1      ppm      (first extraction)           and 0.05 ppm (third

 

-Do-

 

pipes for use in underground drainage                            and sewerage system

pipes for use in underground drainage and sewerage system - Specification

extraction)

 

C. 3.

Structured - wall plastics piping systems for non- pressure drainage and sewerage

IS 16098(Part 1):2013 Structured - wall plastics piping systems for non- pressure drainage and sewerage – Specification: Part 1 Pipes and fittings with smooth external surface, Type A

1      ppm      (first extraction)           and 0.05 ppm (third extraction)

 

 

-Do-


i The latest version of Indian Standards including the amendments issued thereof, as published and notified by the Bureau from time to time, shall be applicable from the date as notified by the Bureau.

 

 

-->

Lead Stabilizer In Polyvinyl Chloride (Pvc) Pipes And Fittings (Amendment) Rules, 2022

 

[04 May 2022]

 

G.S.R. 334(E).-In exercise of the powers conferred by sections 3 and 6 of the Environment (Protection) Act, 1986 (29 of 1986) read with rule 13 of the Environment (Protection) Rules, 1986, the Central Government hereby makes the following rules to amend the Lead Stabilizer in Polyvinyl Chloride (PVC) Pipes and Fittings Rules, 2021, namely.

Rule - 1. Short title and commencement.

 

(1)     These rules may be called the Lead Stabilizer in Polyvinyl Chloride (PVC) Pipes and Fittings (Amendment) Rules, 2022.

 

(2)     They shall come into force six months from the date of notification in the Official Gazette.

Rule - 2.

 

In the Lead Stabilizer in Polyvinyl Chloride (PVC) Pipes and Fittings Rules 2021 (hereinafter referred to as the said rules), in rule 2,-

 

(a)      in sub-rule(1), for the words, brackets and figure "provided in column (3)", the words, brackets and figure "provided in column (4)", shall be substituted;

 

(b)      for sub-rule (2), the following sub-rule shall be substituted, -

 

(i)       The manufacturer shall submit water test report of pipes and fittings carried out by authorised agencies for testing as per sub-rule (1) of rule 4, to respective State Pollution Control Board or Pollution Control Committee in accordance with the consent to operate granted by respective State Pollution Control Board or Pollution Control Committee subject to the provision of the Water (Prevention and Control of Pollution) Act, 1974 (6 of 1974):

Provided that the manufacturer having valid licence from Bureau of Indian Standards for manufacturing of all such Polyvinyl Chloride Pipes and Fittings, and having all such Polyvinyl Chloride Pipes and Fittings marked with "Standard Mark" in accordance with the specification provided in the Licencse issued by the Bureau of Indian Standards, shall be exempted from submission of such test report.

(ii)      Every manufacturer and every importer of Polyvinyl Chloride Pipes and Fittings for every product under the respective Category A, B, and C specified in the Schedule shall comply with the conditions mentioned in that Schedule with respect to IS code of Bureau of Indian Standard or equivalent which are presently available or shall be developed in the future.

 

Explanation.- For the purposes of this rule and rule 3, "manufacturer" means manufacturer of Polyvinyl Chloride Pipes and Fittings situated within the territory of India or outside the territory of India.

 

Rule - 3.

 

In rule 3 of the said rules, in sub- rule (3), for the words "A Panel", the words "A Panel including a representative from manufacturer", shall be substituted.

Rule - 4.

 

In rule 4 of the said rules, for sub- rule (1), the following sub-rule (I) shall be substituted namely.

 

(I)      "The Laboratories accredited by National Accreditation Board for Testing and Calibration Laboratories shall be authorised to carry out such tests as are necessary to ascertain the compliance of rule 2".

Rule - 5.

 

In the said rules, for the Schedule, the following Schedule shall be substituted, namely.

 

"SCHEDULE

 

(See rules 2 and 5)

 

LIST OF PVC PIPES AND FITTINGS AND CORRESPONDING INDIAN STANDARDS PUBLISHED BY THE BIS

 

Sl. No.

Item

Indian Standard No. and Titlei

Lead extraction limits as on date of notification

Date of application of prohibition

(1)

(2)

(3)

(4)

(5)

CATEGORY A:Use of PVC Pipes and Fittings for Potable Water Supply

A. 1.

Unplasticised PVC pipes for Potable water supplies

Type A of IS 4985:2021 Unplasticised PVC pipes for water supplies - Specification                                      (fourth revision)

1      ppm      (first extraction)           and 0.05 ppm (third extraction)

After one year from the date of publication of these rules

A. 2.

Unplasticized polyvinyl chloride (PVC-U) screen and casing pipes for bore/tubewells

IS 12818:2010 Unplasticized polyvinyl chloride (PVC-U) screen and casing pipes for bore/tubewells                       - Specification             (second revision)

1      ppm      (first extraction)           and 0.05 ppm (third extraction)

 

 

-Do-

A. 3.

Chlorinated polyvinyl chloride (CPVC) pipes for potable hot and cold water distribution supplies

IS 15778:2007 Chlorinated            polyvinyl chloride (CPVC) pipes for potable hot and cold water distribution supplies – Specification

1      ppm      (first extraction)           and 0.05 ppm (third extraction)

 

 

-Do-

A. 4.

Oriented unplasticized polyvinyl chloride (PVC-O) pipes for water supply

IS 16647:2017 Oriented            unplasticized polyvinyl chloride (PVC-O) pipes for water supply - Specification

1      ppm      (first extraction)           and 0.05 ppm (third extraction)

 

-Do-

A. 5.

Fabricated PVC-U fittings for potable water supplies

IS     10124     (Parts     1     to 13):2009 Fabricated PVC-U fittings for potable water supplies Specification             (second revision)

1      ppm      (first extraction)           and 0.05 ppm (third extraction)

 

-Do-

A. 6.

Injection moulded PVC socket fittings with solvent cement joints for water supplies

IS 7834(Parts 1 to 8):1987 Specification for injection moulded PVC socket fittings with solvent cement joints for water supplies (first revision)

1      ppm      (first extraction) and 0.05 ppm (third extraction)

 

-Do-

A.7.

Chlorinated polyvinyl chloride (CPVC) fitting for potable hot and cold water distribution supplies

IS 17546:2021 Chlorinated polyvinyl chloride (CPVC) fitting for potable hot and cold water distribution supplies – specification

1 ppm (first extraction) and 0.05 ppm (third extraction)

 

 

-Do-

 

CATEGORY B: Use of PVC Pipes and Fittings in Agriculture and in Suction and Delivery Lines of Agricultural Pumps and Rain Water Systems

(1)

(2)

(3)

(4)

(5)

B. 1.

Unplasticized PVC pipes                              for agriculture

Type B of IS 4985:2021 Unplasticized PVC pipes for water supplies - Specification                                      (fourth revision)

1      ppm      (first extraction)           and 0.05 ppm (third extraction)

After three years from the date of publication of these rules

B. 2.

Unplasticized PVC pipes for use in suction                            and delivery lines of agricultural pump sets

IS 12231:1987 Specification                      for unplasticized PVC pipes for use in suction and delivery lines of agricultural pump sets

1      ppm      (first extraction)           and 0.05 ppm (third extraction)

 

-Do-

B. 3.

UPVC pipe fittings to be used with the UPVC pipes in the suction                            and delivery   lines   of agricultural pumps

IS 13593:1992 Specification for UPVC pipe fittings to be used with the UPVC pipes in the suction and delivery lines of agricultural pumps

1      ppm      (first extraction)           and 0.05 ppm (third extraction)

 

-Do-

B. 4.

Flexible            PVC pipes                   polymer reinforced thermoplastic hoses for suction and delivery lines of          agricultural pumps

IS 15265:2003 Flexible PVC pipes polymer                                reinforced thermoplastic hoses for suction and delivery lines of agricultural pumps - Specification

1      ppm      (first extraction)           and 0.05 ppm (third extraction)

 

 

-Do-

B. 5.

Unplasticized polyvinyl chloride (PVC-U) pipes for soil and discharge system for inside and                      outside buildings including ventilation and rain water system

IS 13592:2013 Unplasticized polyvinyl chloride (PVC-U) pipes for soil and discharge system for inside and outside buildings                  including ventilation and rain water system – Specification (first revision)

1      ppm      (first extraction)           and 0.05 ppm (third extraction)

 

 

-Do-

B. 6.

Unplasticized polyvinyl chloride (UPVC) injection moulded      fittings for soil and waste discharge     system for      inside                  and outside           buildings including ventilation and rain water system

IS 14735:1999 Unplasticized polyvinyl chloride (UPVC) injection moulded fittings for soil and waste discharge system for inside and outside buildings including ventilation and rain water system - Specification

1      ppm      (first extraction)           and 0.05 ppm (third extraction)

 

 

-Do-

CATEGORY C: Use of PVC Pipes and Fittings for Drainage and Sewarage System

(1)

(2)

(3)

(4)

(5)

C. 1.

Unplasticized polyvinyl chloride UPVC single wall corrugated      pipes for drainage

IS 9271:2004 Unplasticized polyvinyl chloride UPVC single wall corrugated pipes for drainage - Specification (first revision)

1      ppm      (first extraction)           and 0.05 ppm (third extraction)

After four years from the date of publication of these rules

C. 2.

Unplasticized non- pressure polyvinyl chloride   (PVC-U)

IS 15328:2003 Unplasticized non-pressure polyvinyl chloride (PVC-U)

1      ppm      (first extraction)           and 0.05 ppm (third

 

-Do-

 

pipes for use in underground drainage                            and sewerage system

pipes for use in underground drainage and sewerage system - Specification

extraction)

 

C. 3.

Structured - wall plastics piping systems for non- pressure drainage and sewerage

IS 16098(Part 1):2013 Structured - wall plastics piping systems for non- pressure drainage and sewerage – Specification: Part 1 Pipes and fittings with smooth external surface, Type A

1      ppm      (first extraction)           and 0.05 ppm (third extraction)

 

 

-Do-


i The latest version of Indian Standards including the amendments issued thereof, as published and notified by the Bureau from time to time, shall be applicable from the date as notified by the Bureau.